The flow rectification of a vaned microdiffuser: A numerical investigation
Authors:
- 1 January 2010
- journal article
- research article
- Published by Taylor & Francis in Journal of the Chinese Institute of Engineers
- Vol. 33 (1) , 1-13
Abstract
This paper presents a numerical investigation to characterize the flow rectification of a dynamic vaned microdiffuser pump. To study the impacts of vane configuration in microscale, two vanes stretching from the inlet region to the outlet region are added to divide the microdiffuser into three flowing passages. By imposing a sinusoidal pressure at the inlet, two geometric parameters are considered: half angle of the diverging section θ and half angle between adjacent vanes F. We find that when the angle between adjacent vanes remains the same (fixed F), net flow rate is augmented with increasing θ. In contrast, there exists an optimized vane configuration while the diverging section is unchanged (fixed θ). For F < θ/3, increase in F helps to improve flow rectification. For F > θ/3, further increase of F results in narrower side passages, and net flow rate diminishes consequently. Hence, best flow rectification is achieved when the diverging section is equally divided by the vanes, i.e. F = θ/3. The influences of vane configuration in flow rectification can be categorized into three regimes: central passage dominated, best rectification, and side passage dominated.Keywords
This publication has 17 references indexed in Scilit:
- Improvement of rectification effects in diffuser/nozzle structures with viscoelastic fluidsBiomicrofluidics, 2008
- Aspect Ratio Effects on Turbulent and Transitional Flow in Rectangular Microchannels as Measured With MicroPIVJournal of Fluids Engineering, 2005
- Low Reynolds number flow through nozzle-diffuser elements in valveless micropumpsSensors and Actuators A: Physical, 2004
- Liquid flow in microchannels: experimental observations and computational analyses of microfluidics effectsJournal of Micromechanics and Microengineering, 2003
- Hydrodynamic Focusing for a Micromachined Flow CytometerJournal of Fluids Engineering, 2001
- Numerical and experimental studies of flat-walled diffuser elements for valve-less micropumpsSensors and Actuators A: Physical, 2000
- The Fluid Mechanics of Microdevices—The Freeman Scholar LectureJournal of Fluids Engineering, 1999
- Microdiffusers as dynamic passive valves for micropump applicationsSensors and Actuators A: Physical, 1998
- Micromachined flat-walled valveless diffuser pumpsJournal of Microelectromechanical Systems, 1997
- Vane Systems for Very-Wide-Angle Subsonic DiffusersJournal of Basic Engineering, 1964