Novel Approaches of DGA to Transformers Filled with Natural Ester Based Insulating Oils
Authors:
- 1 September 2018
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Abstract
Vegetable insulating oils have different chemical compositions as compared to mineral oils, hence, dissolved gas characteristics under thermal and electrical faults have differences, thus fault diagnostic methods based on Dissolved gas analysis (DGA) used for mineral oil-filled transformers cannot be used to investigate vegetable oil-filled transformers. This paper presents experimental results of dissolved gases in the camellia insulating oil under typical thermal and electrical faults in transformers. The thermal fault simulation experiments include low temperature, medium temperature and high temperature, and the electrical fault simulation experiments include partial, breakdown and arc discharges. Experimental results show that except CO and CO 2 , H 2 and C 2 H 6 were main characteristic gases under thermal faults, the percentage contents of H 2 decreases while CH 4 , C 2 H 4 and C 2 H 6 increases with the temperature increase. In addition, H 2 and CH 4 were main characteristic gases under partial discharge faults, C 2 H 2 was the main characteristic gas under breakdown faults, and C 2 H 2 and C 2 H 4 were main characteristic gases under arc discharge faults. Characteristic parameters were extracted based on DGA, and fault diagnostic methods of camellia insulating oil-filled transformer were proposed, including graphic diagnostic method and none code diagnostic method. Results showed that faults could be effectively analyzed by triangle and pentagon diagnostic methods as well as none code diagnostic method. H 2 , C 2 H 4 , C 2 H 2 &H 2 , CH 4 , C 2 H 6 Triangle method and none code diagnostic method are better fault diagnostic methods for camellia insulating oil.Keywords
This publication has 12 references indexed in Scilit:
- The duval pentagon-a new complementary tool for the interpretation of dissolved gas analysis in transformersIEEE Electrical Insulation Magazine, 2014
- DGA comparison between ester and mineral oilsIEEE Transactions on Dielectrics and Electrical Insulation, 2012
- A Review of Dissolved Gas Analysis in Power TransformersEnergy Procedia, 2012
- Dissolved gas analysis of alternative dielectric fluids under thermal and electrical stress2011
- Dissolved gas analysis for common transformer faults in soy seed-based oilIET Electric Power Applications, 2011
- Preliminary results for dissolved gas levels in a vegetable oil-filled power transformerIEEE Electrical Insulation Magazine, 2010
- The duval triangle for load tap changers, non-mineral oils and low temperature faults in transformersIEEE Electrical Insulation Magazine, 2008
- Dissolved gas analysis of alternative fluids for power transformersIEEE Electrical Insulation Magazine, 2007
- Interpretation of gas-in-oil analysis using new IEC publication 60599 and IEC TC 10 databasesIEEE Electrical Insulation Magazine, 2001
- Partial discharge tests using CIGRE method IIIEEE Transactions on Dielectrics and Electrical Insulation, 2000