Abstract
The transformer-coupled LC inversion generator (TCLCG) presented here is based on a modified alternative circuit topology, featuring a parallel connection of the transformers and the complete elimination of the even-numbered storage capacitors in the circuit. This modification significantly reduces the rise time of the generator output signal. An earlier iteration of a 4-stage version was expanded to 5 stages, and ultimately, to a 6-stage version, which was then embedded in an insulating fluid to enhance operational safety. All transformers underwent a comprehensive rewiring process. The generator demonstrated an average efficiency of 34.5%, which corresponds to a gain of 4.14, when subjected to a resistive load of $894 \mathrm{k} \Omega$ and a charging voltage of 34.55 kV. The generator output energy of the 6-stage version was found to be 9.28 J, which is 25% higher than the 5-stage version and 47% higher than the 4-stage version. The average peak voltage was 143 kV, and the average peak-to-peak voltage was 235 kV. The output rise time of the generator remained largely constant at about 22 ns when compared to the 4-stage and 5-stage versions. During the course of the experiments, the optimal shots achieved a peak voltage of 210 kV and a peak-peak voltage of 307 kV. In addition, successful proof-of-concept tests were carried out on the operation of the TCLCG on an electrical load consisting of a low-ohmic resistor of 126Ω, combined with an upstream-paired liquid dielectric peaking spark gap. A pulse steepening from about 31 ns to 4.8 ns, equal to a pulse compression factor in the order of 6.5, was achieved. This result is an initial step in the operation of a TCLCG with a pulse-forming network.

This publication has 3 references indexed in Scilit: