Establishment of recurrent exposures reference levels for repeated computed tomography examinations in adult patients on a nationwide level in Slovakia
Authors:
- 5 December 2024
- journal article
- research article
- Published by Springer Nature in European Radiology
- Vol. 35 (3) , 1658-1668
Abstract
Introduction The study aims were: (1) to assess the incidence in 1 year, the cumulative incidences and the period prevalence in 3/5 years of the condition of patients accruing cumulative effective dose (CED) ≥ 100 mSv in health care centres providing CT examinations in Slovakia; and (2) to quantify their variability among different centres, to test the feasibility of establishing recurrent exposure reference levels (RERL) on a nationwide level. Materials and methods The data were tracked during five consecutive years using the CT dose index and dose-length-product along with the patient’s ID. ED was calculated using conversion factors. Hospitals were stratified according to the number of beds in clinics (0), small (< 200), medium (201–500), or large (> 500) hospitals. Results The database included 1,278,928 patients who underwent 2,157,508 CT exams in 5 years. The I100;1 (%), I100;3 (%), I100;5 (%) ranged from 0% to 6.2%, from 0.3% to 23.2% and from 0.3% to 36.9%, respectively. The P100;3 (%), P100;5 (%) ranged from 0.17% to 13.3% and from 0.19% to 17.8%, respectively. No significant differences were found in epidemiological indexes among different hospital sizes. A strong positive correlation was found between the third quartile values of yearly CED and I100;1 (%) (r = 0.84; R2 = 0.70; p < 0.0001). RERL value, set as the 75th percentiles of the distributions of the 3rd quartiles of the yearly CED, amounted to 25.7 mSv. Conclusion The management of patients with recurrent CT exposures is highly variable among hospitals and unrelated to the size of the institution. Incidence should be reported instead of prevalence. Key Points Question Beyond just reporting statistics on recurrent imaging, the question which needs to be addressed is how to use such information to optimise patient protection. Findings In Slovakia the 5-year incidence of patients with CED ≥ 100 mSv average 6% and range from 0.3% to 36.9% among different hospitals. Clinical relevance The incidence of patients with CED ≥ 100 mSv is highly variable among hospitals and unrelated to their size. The heterogeneity in the radiation exposure of recurrent patients prompts the introduction of RERL to aid in the optimisation of patient protection.Keywords
This publication has 13 references indexed in Scilit:
- Optimisation of protection in the medical exposure of recurrent adult patients due to computed tomography procedures: development of recurrent exposures reference levelsEuropean Radiology, 2023
- Cumulative radiation exposure from multimodality recurrent imaging of CT, fluoroscopically guided intervention, and nuclear medicineEuropean Radiology, 2023
- Assessment of patients’ cumulative doses in one year and collective dose to population through CT examinationsEuropean Journal of Radiology, 2021
- Cumulative effective dose from recurrent CT examinations in Europe: proposal for clinical guidance based on an ESR EuroSafe Imaging surveyEuropean Radiology, 2021
- Patients undergoing multiphase CT scans and receiving a cumulative effective dose of ≥ 100 mSv in a single episode of careEuropean Radiology, 2021
- Estimates of the number of patients with high cumulative doses through recurrent CT exams in 35 OECD countriesPhysica Medica, 2020
- European trends in radiology: investigating factors affecting the number of examinations and the effective doseLa radiologia medica, 2019
- Patients undergoing recurrent CT scans: assessing the magnitudeEuropean Radiology, 2019
- Multinational data on cumulative radiation exposure of patients from recurrent radiological procedures: call for actionEuropean Radiology, 2019
- Quantities used in radiological protectionAnnals of the ICRP, 1991