Refractive corneal inlay implantation outcomes: a preliminary systematic review
- 2 October 2021
- journal article
- review article
- Published by Springer Nature in International Ophthalmology
- Vol. 42 (2) , 713-722
Abstract
Purpose To review all case series of refractive corneal inlay implantation: Flexivue (Presbia, Netherlands), Invue (BioVision, Brügg, Switzerland) and Icolens (Neoptics, Hünenberg, Switzerland) performed in presbyopia patients and to evaluate the reported visual outcomes. In addition, our aim is to provide assessment for complications and to report the satisfaction rates. Methods PubMed, Web of Science and Scopus databases were consulted using “refractive corneal inlay”, “Flexivue Inlay”, “Invue Inlay” and “Icolens inlay” as keywords. 147 articles were found, and they were assessed considering the inclusion and exclusion criteria. After filtering, this systemic review included ten articles, published between 2011 and 2020. Results 308 eyes from 308 participants were enrolled in this systematic review. Mean maximum follow-up was 13.9 months. Nine of the ten case series included used femtosecond laser for the corneal pocket creation. Mean pocket depth was 293.75 µm. 77.5% of the eyes reported a postoperative uncorrected near visual acuity of 20/32 or better, and 19.20% of the inlay-implanted eyes achieved an uncorrected distance visual acuity of 20/20 or better. The most prominent complications were halos, pain, photophobia, and poor distance visual acuity. 27 eyes (8.7%) had to be explanted due to complications, such as near-distance spectacle dependence or blurred distance vision. Conclusion Refractive corneal inlay outcomes demonstrated high efficacy, safety, and satisfaction rates. Furthermore, it is a reversible technique. However, the findings must be viewed with caution due potential conflict of interest. Further research with higher sample size is needed to validate these findings.Keywords
This publication has 31 references indexed in Scilit:
- Femtosecond Laser-Assisted Cataract Surgery After Implantation of a Transparent Near Vision Corneal InlayJournal of Refractive Surgery, 2015
- The methodological quality assessment tools for preclinical and clinical studies, systematic review and meta‐analysis, and clinical practice guideline: a systematic reviewJournal of Evidence-Based Medicine, 2015
- Corneal inlays for presbyopia correctionCurrent Opinion in Ophthalmology, 2013
- Visual Outcomes and Safety of a Refractive Corneal Inlay for Presbyopia Using Femtosecond LaserJournal of Refractive Surgery, 2013
- LASIK Interface Complications: Etiology, Management, and OutcomesJournal of Refractive Surgery, 2012
- Visual Outcomes and Safety of a Small Diameter Intrastromal Refractive Inlay for the Corneal Compensation of PresbyopiaJournal of Refractive Surgery, 2012
- IntraLase Femtosecond Laser vs Mechanical Microkeratomes in LASIK for Myopia: A Systematic Review and Meta-analysisJournal of Refractive Surgery, 2012
- Femtosecond Laser–assisted Corneal Pocket Creation Using a Mask for Inlay ImplantationJournal of Refractive Surgery, 2011
- Intracorneal inlay to correct presbyopia: Long-term resultsJournal of Cataract & Refractive Surgery, 2011
- The PRISMA Statement for Reporting Systematic Reviews and Meta-Analyses of Studies That Evaluate Health Care Interventions: Explanation and ElaborationPLOS Medicine, 2009