Superior fixation of pegged trabecular metal over screw-fixed pegged porous titanium fiber mesh
Open Access
- 24 March 2011
- journal article
- research article
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 82 (2) , 177-186
Abstract
Background and purpose Lasting stability of cementless implants depends on osseointegration into the implant surface, and long-term implant fixation can be predicted using radiostereometric analysis (RSA) with short-term follow-up. We hypothesized that there would be improved fixation of high-porosity trabecular metal (TM) tibial components compared to low-porosity titanium pegged porous fiber-metal (Ti) polyethylene metal backings. Methods In a prospective, parallel-group, randomized unblinded clinical trial, we compared cementless tibial components in patients aged 70 years and younger with osteoarthritis. The pre-study sample size calculation was 22 patients per group. 25 TM tibial components were fixed press-fit by 2 hexagonal pegs (TM group) and 25 Ti tibial components were fixed press-fit and by 4 supplemental screws (Ti group). Stereo radiographs for evaluation of absolute component migration (primary effect size) and single-direction absolute component migration (secondary effect size) were obtained within the first postoperative week and at 6 weeks, 6 months, 1 year, and 2 years. American Knee Society score was used for clinical assessment preoperatively, and at 1 and 2 years. Results There were no intraoperative complications, and no postoperative infections or revisions. All patients had improved function and regained full extension. All tibial components migrated initially. Most migration of the TM components (n = 24) occurred within the first 3 months after surgery whereas migration of the Ti components (n = 22) appeared to stabilize first after 1 year. The TM components migrated less than the Ti components at 1 year (p = 0.01) and 2 years (p = 0.004). Interpretation We conclude that the mechanical fixation of TM tibial components is superior to that of screw-fixed Ti tibial components. We expect long-term implant survival to be better with the TM tibial component.Keywords
This publication has 53 references indexed in Scilit:
- Experimental and clinical performance of porous tantalum in orthopedic surgeryBiomaterials, 2006
- The premature failure of the Charnley Elite-Plus stemThe Journal of Bone and Joint Surgery. British volume, 2006
- Biomechanical analysis of the shear behaviour adjacent to an axially loaded implantJournal of Biomechanics, 2006
- The influence of surface porosity on gap-healing around intra-articular implants in the presence of migrating particlesBiomaterials, 2005
- Guidelines for standardization of radiostereometry (RSA) of implantsActa Orthopaedica, 2005
- Age‐related variations in the microstructure of human tibial cancellous boneJournal of Orthopaedic Research, 2002
- The Swedish Knee Arthroplasty Register 1975-1997: An update with special emphasis on 41,223 knees operated on in 1988-1997Acta Orthopaedica, 2001
- Sealing effect of hydroxyapatite coating: A 12-month study in caninesActa Orthopaedica, 2000
- An internally cooled saw blade for bone cuts: Lower temperatures in 30 knee arthroplastiesActa Orthopaedica, 1990
- The effect of movement on the bonding of porous metal to boneJournal of Biomedical Materials Research, 1973