X-ray emission frompinches atA: Current scaling, gap closure, and shot-to-shot fluctuations
Authors:
- H. C. IvesHIH. C. Ives
- D. L. FehlDFD. L. Fehl
- M. E. CuneoMCM. E. Cuneo
- M. G. MazarakisMMM. G. Mazarakis
- J. E. BaileyJBJ. E. Bailey
- G. R. BennettGBG. R. Bennett
- D. E. BlissDBD. E. Bliss
- G. A. ChandlerGCG. A. Chandler
- R. J. LeeperRLR. J. Leeper
- M. K. MatzenMMM. K. Matzen
- D. H. McDanielDMD. H. McDaniel
- 14 April 2004
- journal article
- research article
- Published by American Physical Society (APS) in Physical Review E
- Vol. 69 (4) , 046403
Abstract
We have measured the x-ray power and energy radiated by a tungsten-wire-array pinch as a function of the peak pinch current and the width of the anode-cathode gap at the base of the pinch. The measurements were performed at 13- and 19-MA currents and 1-, 2-, 3-, and 4-mm gaps. The wire material, number of wires, wire-array diameter, wire-array length, wire-array-electrode design, normalized-pinch-current time history, implosion time, and diagnostic package were held constant for the experiments. To keep the implosion time constant, the mass of the array was increased as (i.e., the diameter of each wire was increased as where is the peak pinch current. At 19 MA, the mass of the 300-wire 20-mm-diam 10-mm-length array was 5.9 mg. For the configuration studied, we find that to eliminate the effects of gap closure on the radiated energy, the width of the gap must be increased approximately as For shots unaffected by gap closure, we find that the peak radiated x-ray power the total radiated x-ray energy the x-ray-power rise time and the x-ray-power pulse width Calculations performed with a time-dependent model of an optically thick pinch at stagnation demonstrate that the internal energy and radiative opacity of the pinch are not responsible for the observed subquadratic power scaling. Heuristic wire-ablation arguments suggest that quadratic power scaling will be achieved if the implosion time is scaled as The measured 1σ shot-to-shot fluctuations in and are approximately 12%, 9%, 26%, 9%, and 2%, respectively, assuming that the fluctuations are independent of These variations are for one-half of the pinch. If the half observed radiates in a manner that is statistically independent of the other half, the variations are a factor of less for the entire pinch. We calculate the effect that shot-to-shot fluctuations of a single pinch would have on the shot-success probability of the double-pinch inertial-confinement-fusion driver proposed by Hammer et al. [Phys. Plasmas 6, 2129 (1999)]. We find that on a given shot, the probability that two independent pinches would radiate the same peak power to within a factor of (where is equal to where σ is the 1σ fractional variation of the peak power radiated by a single pinch. Assuming α must be to achieve adequate odd-Legendre-mode radiation symmetry for thermonuclear-fusion experiments, σ must be for the shot-success probability to be The observed fluctuation in would provide adequate symmetry on 44% of the shots. We propose that three-dimensional radiative-magnetohydrodynamic simulations be performed to quantify the sensitivity of the x-ray emission to various initial conditions, and to determine whether an imploding pinch is a spatiotemporal chaotic system.
Keywords
This publication has 125 references indexed in Scilit:
- Z pinches—A historical viewLaser and Particle Beams, 2001
- A role for electron viscosity in plasma shock heatingPhysics of Plasmas, 2001
- Z pinch driven inertial confinement fusion target physics research at Sandia National LaboratoriesNuclear Fusion, 1999
- Obtaining absolute spatial flux measurements with a time-resolved pinhole cameraReview of Scientific Instruments, 1999
- On the transparency of foam in low-density foam Z-pinch experimentsReview of Scientific Instruments, 1999
- Measurement of the photon field, E>150 eV on Sandia’s Z FacilityReview of Scientific Instruments, 1999
- Axial diagnostic package for ZReview of Scientific Instruments, 1999
- Absolute, soft x-ray calorimetry on the Z facility at Sandia National Laboratories (invited)Review of Scientific Instruments, 1999
- Streaked laser absorption measurements of density and temperature profiles in a high density Z pinchReview of Scientific Instruments, 1995
- Characterization of a high‐speed x‐ray imager (abstract)a)Review of Scientific Instruments, 1995