Secondary Electrospray Ionization-Ion Mobility Spectrometry for Explosive Vapor Detection
Authors:
- 22 April 2004
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 76 (10) , 2741-2747
Abstract
The unique capability of secondary electrospray ionization (SESI) as a nonradioactive ionization source to detect analytes in both liquid and gaseous samples was evaluated using aqueous solutions of three common military explosives: cyclo-1,3,5-trimethylene-2,4,6-trinitramine (RDX), nitroglycerin (NG) and pentaerythritol tetranitrate (PETN). The adducts formed between the compounds and their respective dissociation product, RDX·NO2-, NG·NO3-, and PETN·NO3-, gave the most intense signal for the individual compound but were more sensitive to temperature than other species. These autoadducts were identified as RDX·NO2-, NG·NO3-, and PETN·NO3- and had maximum signal intensity at 137, 100, and 125 °C, respectively. The reduced mobility values of the three compounds were constant over the temperature range from 75 to 225 °C. The signal-to-noise ratios for RDX, NG, and PETN at 50 mg L-1 in methanol−water were 340, 270, and 170, respectively, with a nominal noise of 8 ± 2 pA. In addition to the investigation of autoadduct formation, the concept of doping the ionization source with nonvolatile adduct-forming agents was investigated and described for the first time. The SESI-IMS detection limit for RDX was 116 μg L-1 in the presence of a traditional volatile chloride dopant and 5.30 μg L-1 in the presence of a nonvolatile nitrate dopant. In addition to a lower detection limit, the nitrate dopant also produced a greater response sensitivity and a higher limit of linearity than did the traditional volatile chloride dopant.Keywords
This publication has 20 references indexed in Scilit:
- Analysis of 2,4,6-trinitrotoluene, pentaerythritol tetranitrate and cyclo-1,3,5-trimethylene-2,4,6-trinitramine using negative corona discharge ion mobility spectrometryTalanta, 2003
- A rapid and efficient mass spectrometric method for the analysis of explosivesRapid Communications in Mass Spectrometry, 2002
- Evaluation of sulfonylurea herbicides using high resolution electrospray ionization ion mobility quadrupole mass spectrometryField Analytical Chemistry & Technology, 2001
- Characterisation of the ion mobility spectrometric behaviour of a dinitrobutane under varying conditions of temperature and concentrationAnalytica Chimica Acta, 1998
- Quantitative calibration of vapor levels of TNT, RDX, and PETN using a diffusion generator with gravimetry and ion mobility spectrometryTalanta, 1997
- Design and calibration of pulsed vapor generators for 2,4,6-trinitrotoluene, cyclo-1,3,5-trimethylene-2,4,6-trinitramine, and pentaerythritol tetranitrateAnalytical Chemistry, 1993
- Detection of ethylene glycol dinitrate vapors by ion mobility spectrometry using chloride reagent ionsAnalytical Chemistry, 1988
- Alternative reagent ions for plasma chromatographyAnalytical Chemistry, 1984
- Electron spin resonanceAnalytical Chemistry, 1978
- Absolute Values of the Electron Mobility in HydrogenPhysical Review B, 1936