Three-Dimensional CMOS Differential Folded Hall Sensor With Bandgap Reference and Readout Circuit
- 24 November 2017
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 18 (2) , 517-527
Abstract
This paper presents a 3-D differential folded Hall sensor (HS) fabricated using standard 0.18-μm CMOS technology; this HS includes 1-D folded lateral Hall sensor (FLHS) and 2-D folded vertical Hall sensor (FVHS). The proposed 3-D HS is laterally folded to reduce the effective conduction length and to decrease the offset voltage; a p + guard ring is used to narrow the conducting channel and to improve magnetosensitivity. The magnetosensitivity is improved two-fold and the offset is eliminated using the differential topology. The proposed 1-D FLHS is sensitive to magnetic induction perpendicular to the chip plane B Z through the fast accumulation-slow release mechanism; the proposed 2-D FVHS is responsive to magnetic induction parallel to the chip plane, B X and B Y , based on the interaction between the magnetoresistor (MR) and magnetotransistor, where MR is more dominant. Notably, the proposed 3-D HS operates with a small offset voltage of 0.26 mV and without magnetic hysteresis. For 2-D FVHS, at a voltage gain of 89.6 dB, the maximum sensor output ΔV H is approximately 196.4 mV at the applied magnetic induction of 5 mT and the maximum supply-current-related sensitivity S RI is approximately 5943 V/A·T at a current consumption of 6.25 mA for x- or y-channel. For 1-D FLHS, the maximum ΔV H is approximately 470.8 mV at 5 mT and the maximum S RI is approximately 14790 V/A·T at a bias current of 6.25 mA for z-channel. The magnetosensitivity S RI of 1-D FLHS is approximately 2.35 times that of 2-D FVHS. The designed 1-D FLHS is a comparable to the performance of other publications. However, it experiences a high nonlinearity error in output Hall voltage at a low bias current. By contrast, the proposed 1-D FLHS has a linear performance in output Hall voltage at a high bias current.Keywords
Funding Information
- Ministry of Science and Technology (MOST 103-2622-E-027-014-CC3)
This publication has 32 references indexed in Scilit:
- The effect of deviation current to 5-contacts vertical Hall device2016
- Hall Effect Devices with Three Terminals: Their Magnetic Sensitivity and Offset Cancellation SchemeJournal of Sensors, 2016
- High resolution, low offset Vertical Hall device in low-voltage CMOS technology2015
- Novel High Gain Low Noise CMOS Instrumentation Amplifier for Biomedical Applications2013
- Extracting 3D Magnetic Field Components With Two Hall Plates on a Piezoelectric Nano Rotary Positioner SystemIEEE Transactions on Applied Superconductivity, 2013
- Comparative Study on the Performance of Five Different Hall Effect DevicesSensors, 2013
- DC suppressed high gain active CMOS instrumentation amplifier for biomedical application2011
- Interaction Between Magnetoresistor and Magnetotransistor in the Longitudinal and Folded Vertical Hall DevicesIEEE Sensors Journal, 2004
- Linearizing integrated Hall devices2002
- High-accuracy analog Hall probeIEEE Transactions on Instrumentation and Measurement, 1997