Intraocular pressure after Descemet’s stripping and non-Descemet’s stripping automated endothelial keratoplasty
Authors:
- 13 March 2011
- journal article
- research article
- Published by Springer Nature in Japanese Journal of Ophthalmology
- Vol. 55 (2) , 98-102
Abstract
To evaluate the effect on intraocular pressure (IOP) of increased corneal thickness after Descemet’s stripping automated endothelial keratoplasty (DSAEK) and of non-Descemet’s stripping automated endothelial keratoplasty (nDSAEK) as measured by four different techniques. Twenty-four eyes (22 patients; mean age, 74.0 years) with successful DSAEK (11 eyes) or nDSAEK (13 eyes) treatment at least 3 months prior to testing were enrolled. IOP was measured with Goldmann applanation tonometry (GAT), dynamic contour tonometry (DCT), pneumatonometry, and Tono-Pen XL (Tonopen). Central corneal thickness (CCT) was measured by ultrasonic pachymetry. These data were used for statistical analysis. Mean IOP measured by GAT, DCT, pneumatonometry, and Tonopen was 14.4, 13.9, 11.2, and 13.2 mmHg, respectively, in the DSAEK group; and 15.0, 14.4, 12.5, and 14.4 mmHg, respectively, in the nDSAEK group. Correlations between IOP and CCT were not statistically significant in either group. Pressure measured by pneumatonometry was significantly and consistently lower than that obtained by the other three methods. For both DSAEK and nDSAEK, IOP readings by the four tonometers seem to be unrelated to artificially thickened corneas.Keywords
This publication has 26 references indexed in Scilit:
- In Vivo Laser Confocal Microscopy After Descemet Stripping with Automated Endothelial KeratoplastyAmerican Journal of Ophthalmology, 2008
- Intraocular Pressure Measurements Following Descemet Stripping Endothelial KeratoplastyAmerican Journal of Ophthalmology, 2008
- Dynamic contour tonometry: principle and useClinical & Experimental Ophthalmology, 2006
- Comparisons between Pascal dynamic contour tonometry, the TonoPen, and Goldmann applanation tonometry in patients with glaucomaActa Ophthalmologica Scandinavica, 2006
- Comparison of Dynamic Contour Tonometry and Goldmann Applanation Tonometry in Glaucoma Patients and Healthy SubjectsAmerican Journal of Ophthalmology, 2006
- Endothelial Keratoplasty to Restore Clarity to a Failed Penetrating GraftCornea, 2006
- Descemet-Stripping Automated Endothelial KeratoplastyCornea, 2006
- Measuring intraocular pressure-adjustments for corneal thickness and new technologiesCurrent Opinion in Ophthalmology, 2006
- Small-Incision Deep Lamellar Endothelial Keratoplasty (DLEK)Cornea, 2005
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986