Multi-layered electrospun grafts for surgical repair: Biomimicking physiological ascending aortic compliance
Open Access
- 1 January 2025
- journal article
- Published by SAGE Publications in Journal of Applied Biomaterials & Functional Materials
- Vol. 23
Abstract
Commercially available Dacron (woven polyester) grafts are used for routine open surgical repair of thoracic aortic aneurysms. Despite durable and biocompatible, these grafts do not reproduce the natural mechanical properties of the aorta. Therefore, the aim of this project was to develop an innovative graft that additionally exhibits physiological aortic compliance. To achieve this result, multi-layered tubular aortic grafts were created by electrospinning of a thermoplastic polyurethane. To reduce permeability, a gelatin-coating was added. Three groups (G1–3; n = 5) with varying layer designs were evaluated regarding the main mechanical properties of vascular grafts such as suture retention strength, permeability and static and dynamic compliance. G3, which combined electrospinning with a stable silicone-coated inlay was chosen for the fabrication of medical grade thermoplastic polyurethane grafts (Gm; n = 6). Dynamic compliance values of 19.68 ± 11.5%/100 mmHg (50–90 mmHg), 15.18 ± 8.7%/100 mmHg (80–120 mmHg) and 14.56 ± 7.4%/100 mmHg (110–150 mmHg) were achieved. The compliance was higher than for Dacron and ePTFE grafts and comparable to the normal sized ascending aorta of around 16%/100 mmHg in a healthy human and porcine aortic compliance of 14.3%/100 mmHg. Static compliance was successfully tested up to 350 mmHg. No significant changes in graft diameter or delaminations of the graft layers were detected after compliance testing. Therefore, by combining electrospinning with a durable inlay, both elasticity and recoverability are obtained, resulting in a promising alternative to the gold-standard in open-surgical treatment of thoracic aortic pathologies.Keywords
This publication has 37 references indexed in Scilit:
- 4‐Axis 3D‐Printed Tubular Biomaterials Imitating the Anisotropic Nanofiber Orientation of Porcine AortaeAdvanced Healthcare Materials, 2023
- Living Electrospun Short Fibrous Sponge via Engineered Nanofat for Wound HealingAdvanced Fiber Materials, 2022
- Introduction and Historical Overview2019
- Role of Biomaterials in Surgery2019
- Biomimetic coating of cross‐linked gelatin to improve mechanical and biological properties of electrospun PET: A promising approach for small caliber vascular graft applicationsJournal of Biomedical Materials Research Part A, 2017
- Old Myths, New Concerns: the Long-Term Effects of Ascending Aorta Replacement with Dacron Grafts. Not All That Glitters Is GoldJournal of Cardiovascular Translational Research, 2016
- Electrospinning collagen/chitosan/poly(L‐lactic acid‐co‐ϵ‐caprolactone) to form a vascular graft: Mechanical and biological characterizationJournal of Biomedical Materials Research Part A, 2012
- A three-layered electrospun matrix to mimic native arterial architecture using polycaprolactone, elastin, and collagen: A preliminary studyActa Biomaterialia, 2010
- Micrometer scale Ex Vivo multiphoton imaging of unstained arterial wall structureCytometry Part A, 2005
- Effects of carbodiimide crosslinking conditions on the physical properties of laminated intestinal submucosaJournal of Biomedical Materials Research, 2001