A Case of Vanished Buffy Coat in Peripheral Blood Hematopoietic Progenitor Cell Harvest
- 4 August 2026
- journal article
- apheresis illustrated
- Published by Wiley in Journal of Clinical Apheresis
- Vol. 41 (4) , e70164
Abstract
We report on an autologous hematopoietic progenitor cell collection via apheresis (HPC(A)) with adequate CD34+ pre‐count and unexpectedly low collection efficiency resulting in a failed HPC(A) collection. The collection bag contained almost no buffy coat and the plasma was orange. We assess both collection and patient factors that may have contributed to this finding.Keywords
This publication has 3 references indexed in Scilit:
- Overcoming challenges posed by a hypervigilant interface management system during therapeutic plasma exchange: Need for a clinical eye in the era of automationTherapeutic Apheresis and Dialysis, 2024
- Poor harvest of peripheral blood stem cell in donors with microcytic red blood cellsTransfusion, 2012
- The ISHAGE Guidelines for CD34+ Cell Determination by Flow CytometryJournal of Hematotherapy, 1996