An Improved Hybrid DSTATCOM Topology to Compensate Reactive and Nonlinear Loads
- 1 May 2014
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 61 (12) , 6517-6527
Abstract
This paper proposes an improved hybrid distribution static compensator (DSTATCOM) topology to address some practical issues such as power rating, filter size, compensation performance, and power loss. An LCL filter has been used at the front end of a voltage source inverter (VSI), which provides better switching harmonics elimination while using much smaller value of an inductor as compared with the traditional L filter. A capacitor is used in series with an LCL filter to reduce the dc-link voltage of the DSTATCOM. This consequently reduces the power rating of the VSI. With reduced dc-link voltage, the voltage across the shunt capacitor of the LCL filter will be also less. It will reduce the power losses in the damping resistor as compared with the traditional LCL filter with passive damping. Therefore, the proposed DSTATCOM topology will have reduced weight, cost, rating, and size with improved efficiency and current compensation capability compared with the traditional topology. A systematic procedure to design the components of the passive filter has been presented. The effectiveness of the proposed DSTATCOM topology over traditional topologies is validated through both simulation and experimental studies.Keywords
Funding Information
- Department of Science and Technology, India (DST/TM/SERI/2k10/47(G))
This publication has 28 references indexed in Scilit:
- A Noniterative Optimized Algorithm for Shunt Active Power Filter Under Distorted and Unbalanced Supply VoltagesIEEE Transactions on Industrial Electronics, 2012
- A DSTATCOM Topology With Reduced DC-Link Voltage Rating for Load Compensation With Nonstiff SourceIEEE Transactions on Power Electronics, 2012
- Design and Implementation of Four-Leg Voltage-Source-Converter-Based VFC for Autonomous Wind Energy Conversion SystemIEEE Transactions on Industrial Electronics, 2011
- Generalized Frequency Domain Formulation of the Switching Frequency for Hysteresis Current Controlled VSI Used for Load CompensationIEEE Transactions on Power Electronics, 2011
- Modeling and Harmonic Optimization of a Two-Stage Saturable Magnetically Controlled Reactor for an Arc Suppression CoilIEEE Transactions on Industrial Electronics, 2011
- A Lyapunov-Function-Based Control for a Three-Phase Shunt Hybrid Active FilterIEEE Transactions on Industrial Electronics, 2011
- A Hybrid Active Filter for a Three-Phase 12-Pulse Diode Rectifier Used as the Front End of a Medium-Voltage Motor DriveIEEE Transactions on Power Electronics, 2011
- A Transformerless Hybrid Active Filter Using a Three-Level Pulsewidth Modulation (PWM) Converter for a Medium-Voltage Motor DriveIEEE Transactions on Power Electronics, 2010
- Experimental Design of a Nonlinear Control Technique for Three-Phase Shunt Active Power FilterIEEE Transactions on Industrial Electronics, 2010
- DC Capacitor Voltage Equalization in Neutral Clamped Inverters for DSTATCOM ApplicationIEEE Transactions on Industrial Electronics, 2009