Evidences of accumulation points: Effect of high voltage DC conditioning on concave electrodes insulated by large vacuum gaps
- 19 April 2022
- journal article
- conference paper
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 131 (15) , 153302
Abstract
Counterintuitive experimental evidences have been observed during High Voltage Direct Current (HVDC) tests of two concave, axial-symmetric, electrodes insulated by large vacuum gaps of 3 and 7 cm with voltages from 150 to 370 kVdc. The dissipation of microdischarge power during the conditioning procedure occurs mostly on the anodic side in a region close to the axis of the system where the electric field is at a minimum, far from the positions where the breakdowns have been observed. The analyses of the phenomena are carried out by comparing the temporal evolution of voltages, currents, pressure, measurements of x-ray energy spectra, and images from infrared and visible light cameras. Numerical simulations, based on ray-tracing algorithm, correctly identify the positions where the power dissipation of microdischarges occurs. A mutual exchange of charged particles in the electrostatic field between electrodes seems a reasonable physical mechanism to interpret the observations. These findings suggest a new perspective to review the current literature and interpret new results considering geometric details which were so far omitted: the areas with the most intense electric field, typically located on the surfaces of the electrodes under test, are not necessarily the sole surfaces involved in the HVDC conditioning in high vacuum.Keywords
Funding Information
- ITER Organization (ITER-RFX Neutral Beam Testing Facility Argeement (NBTF))
- EUROfusion Consortium (Grant Agreement No 101052200 - EUROfusion)
This publication has 15 references indexed in Scilit:
- Evidences of accumulation points in cascade regenerative phenomena observed in high voltage dc devices insulated by long vacuum gapsJournal of Physics Communications, 2018
- Numerical–Experimental Benchmarking of a Probabilistic Code for Prediction of Voltage Holding in High VacuumIEEE Transactions on Plasma Science, 2017
- The PRIMA Test Facility: SPIDER and MITICA test-beds for ITER neutral beam injectorsNew Journal of Physics, 2017
- Preface to Special Topic: ITERPhysics of Plasmas, 2015
- Energetic high-voltage breakdowns in vacuum over a large gap for ITER neutral beam acceleratorFusion Engineering and Design, 2013
- Voltage Holding Prediction in Multi Electrode-multi Voltage Systems Insulated in VacuumIEEE Transactions on Dielectrics and Electrical Insulation, 2011
- Status of the ITER neutral beam injection system (invited)Review of Scientific Instruments, 2008
- ITER neutral beam systemNuclear Fusion, 2000
- dc voltage holding experiments of vacuum gap for high-energy ion sourcesJournal of Applied Physics, 1992
- On X-Ray Wave-LengthsPhysical Review B, 1915