Feasibility of Occipital Condyle Screw Placement for Occipitocervical Fixation
Authors:
- 1 December 2008
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Spinal Disorders & Techniques
- Vol. 21 (8) , 540-546
Abstract
Study Design Occipital-cervical (OC) stabilization using occipital condyle fixation with a polyaxial screw-rod construct is described. Objectives To describe a novel technique and initial radiographic results for posterior OC fixation using the occipital condyles for cranial fixation. Summary of Background Data Stabilization of the OC junction remains a challenge. Owing to the regional anatomy and the poor occipital bone purchase, multiple attachment points to the occipital bone are required to increase construct rigidity. To address these issues, we propose a novel OC fixation technique using polyaxial occipital condyle screws for cranial purchase. Methods The OC junction was exposed posteriorly in silicone-injected cadaver heads. Polyaxial titanium screws (3.5 mm) were inserted bicortically solely into the occipital condyles; C1 lateral masses and C2 pedicles, or transarticularly through C1-C2, followed by fixation to a 3-mm rod. Drilling was guided by anatomic landmarks and fluoroscopy. Computerized tomography scans were obtained. Condylar screw angles and lengths were analyzed with respect to historical morphometric condyle measurements and with respect to neurovascular structures. Results The condylar entry point was 4 to 5-mm lateral to the foramen magnum on the axial plane, and 1 to 2-mm rostral to the atlantooccipital joint. The mean angle of medialization was 17 degrees (range: 12 to 22 degrees). In the sagittal plane, the maximal superior screw angulation was 5 degrees. The mean screw length to obtain bicortical purchase was 22 mm (range: 20 to 24 mm). The hypoglossal canal was uninterrupted during its full course. The jugular bulb, carotid, and vertebral arteries were not injured by condyle screw placement. No fractures were identified. Conclusion Condyle screws can be placed without injury to neurovascular structures. OC junction fixation using polyaxial occipital condyle screws is feasible and can be considered a salvage technique or an alternative where other fixation techniques are not available.Keywords
This publication has 43 references indexed in Scilit:
- Biomechanics of Occipitocervical FixationSpine, 2006
- A morphometric analysis of the foramen magnum region as it relates to the transcondylar approachActa Neurochirurgica, 2005
- Hajdu—Cheney syndrome and syringomyeliaJournal of Neurosurgery, 2002
- Microvascular decompression of cranial nerves: lessons learned after 4400 operationsJournal of Neurosurgery, 1999
- Microsurgical anatomy of the transcondylar, supracondylar, and paracondylar extensions of the far-lateral approachJournal of Neurosurgery, 1997
- The suboccipital cavernous sinusJournal of Neurosurgery, 1997
- The Role of Plate and Screw Fixation in Occipitocervical Fusion in Rheumatoid ArthritisSpine, 1994
- Posterior Occipitocervical FusionSpine, 1991
- Microsurgical anatomy of the region of the foramen magnumSurgical Neurology, 1985
- Complications of sublaminar wiringSurgical Neurology, 1985