Results of the safety and efficacy of iobitridol in more than 61,000 patients
Authors:
- 1 August 2003
- journal article
- contrast media
- Published by Springer Nature in European Radiology
- Vol. 13 (8) , 2006-2011
Abstract
We present results of a postmarketing surveillance study with iobitridol (Xenetix, Sulzbach, Germany) in more than 61,000 patients from 1996 until 2000. The purpose of this study was the assessment of safety and diagnostic efficacy of the non-ionic contrast agent iobitridol in the setting of a post-marketing surveillance study. Iobitridol (Xenetix) has been registered in Germany since 1996. Between 1996 and 2000 207 radiologists have documented in a questionnaire the routine use of Xenetix in 61,754 patients that have received Xenetix for diagnostic procedures. On each questionnaire parameters regarding demographic data, safety, and diagnostic efficacy were assessed. The data were statistically evaluated and analysed. The examination allowed for a diagnosis in 99% of cases. Image quality was rated as "excellent" or "good" in 89.8% of cases. In obese patients there was a significantly higher percentage (p<0.001) of poor image quality. In 0.1% poor contrast was noted. Of patients, 28.8% had at least one risk factor, and 3.1% had three or more. Adverse events were noted in 2.3% of the examinations, but nearly half of them (1.1%) presented with "feeling of warmth" as the only symptom. Of adverse events, 0.2% were non-transient, and 1 patient died. In 0.2% of patients the procedure was stopped due to adverse events. In 0.9% of patients the causal relationship with the contrast agent was rated as probable (probable+possible=1.1%). The percentage of adverse events (excluding warmth) was independent of iodine concentration and of dose, and was higher in young patients. Xenetix is an efficient contrast agent for radiological procedures and is associated with a low rate of adverse events.Keywords
This publication has 14 references indexed in Scilit:
- Comparative Toxic Effects of Iobitridol and Iohexol on the KidneyInvestigative Radiology, 1998
- Analysis of the Factors Influencing the Osmolality of Eight Monomeric Nonionic Iodinated Contrast Medium MoleculesInvestigative Radiology, 1997
- Deaths related to iodinated contrast media reported spontaneously to the U.S. Food and Drug Administration, 1978-1994: effect of the availability of low-osmolality contrast media.Radiology, 1997
- Evaluation of the clinical safety and efficacy of iobitridol (Xenetix) in intravenous urographyEuropean Journal of Radiology, 1996
- Xenetix--a milestone in diagnostic imaging.1996
- Assessment of the safety and efficacy of iobitridol, an iodinated contrast medium (30% iodine), in cranial CTEuropean Journal of Radiology, 1995
- Safety and Cost Effectiveness of High-Osmolality as Compared with Low-Osmolality Contrast Material in Patients Undergoing Cardiac AngiographyNew England Journal of Medicine, 1992
- Contrast media for angiography: Physicochemical properties, pharmacokinetics and biocompatibilityClinical Materials, 1991
- Adverse reactions to ionic and nonionic contrast media. A report from the Japanese Committee on the Safety of Contrast Media.Radiology, 1990
- The RACR Survey of Intravenous Contrast Media Reactions Final ReportAustralasian Radiology, 1988