An online preconcentration system for the determination of uranium in water and effluent samples
- 16 December 2009
- journal article
- research article
- Published by Springer Nature in Environmental Monitoring and Assessment
- Vol. 171 (1-4) , 163-169
Abstract
Amberlite XAD-4 resin functionalized with β-nitroso-α-naphthol was applied to an online system for the preconcentration and determination of uranium. U (VI) ions were retained on the minicolumn at an appropriate pH and then desorbed with acid solution. The amount of uranium in the eluate was measured spectrophotometrically at 650 nm using Arsenazo III as a colorimetric reagent. The limit of detection and the preconcentration factor were 1.8 μg L − 1 and 10, respectively. The chemical and flow variables affecting the preconcentration were studied. The influence of several ions on the system was also investigated. The method was successfully applied for the evaluation of uranium in water and in effluent samples.Keywords
This publication has 19 references indexed in Scilit:
- Solid phase extraction of gold(III) on silica gel modified with benzoylthiourea prior to its determination by flame atomic absorption spectrometryEnvironmental Monitoring and Assessment, 2008
- Solid phase extractive preconcentration of silver from aqueous samplesEnvironmental Monitoring and Assessment, 2008
- Determination of copper in biological samples by flame atomic absorption spectrometry after precipitation with Me-BTAPEnvironmental Monitoring and Assessment, 2008
- Preconcentration system for cadmium and lead determination in environmental samples using polyurethane foam/Me-BTANCJournal of Hazardous Materials, 2006
- On-Line Preconcentration and Determination of Cadmium, Cobalt and Nickel in Food Samples by Flame Atomic Absorption Spectrometry Using a New Functionalized ResinMicrochimica Acta, 2006
- Factorial design in the optimization of preconcentration procedure for lead determination by FAASTalanta, 2005
- Amberlite XAD-4 functionalized with succinic acid for the solid phase extractive preconcentration and separation of uranium(VI)Talanta, 2004
- Application of Doehlert designs for optimisation of an on-line preconcentration system for copper determination by flame atomic absorption spectrometryTalanta, 2003
- Thorium(IV) and uranium(VI) sorption studies on octacarboxymethyl-C-methylcalix[4]resorcinarene impregnated on a polymeric supportAnalytica Chimica Acta, 2003
- Pre-concentration, separation and trace determination of lanthanum(III), cerium(III), thorium(IV) and uranium(VI) on polymer supported o-vanillinsemicarbazoneAnalytica Chimica Acta, 2001