Clinical feasibility of a myocardial signal intensity threshold-based semi-automated cardiac magnetic resonance segmentation method
- 13 August 2015
- journal article
- research article
- Published by Springer Nature in European Radiology
- Vol. 26 (5) , 1503-1511
Abstract
To assess the accuracy and efficiency of a threshold-based, semi-automated cardiac MRI segmentation algorithm in comparison with conventional contour-based segmentation and aortic flow measurements. Short-axis cine images of 148 patients (55 ± 18 years, 81 men) were used to evaluate left ventricular (LV) volumes and mass (LVM) using conventional and threshold-based segmentations. Phase-contrast images were used to independently measure stroke volume (SV). LV parameters were evaluated by two independent readers. Evaluation times using the conventional and threshold-based methods were 8.4 ± 1.9 and 4.2 ± 1.3 min, respectively (P < 0.0001). LV parameters measured by the conventional and threshold-based methods, respectively, were end-diastolic volume (EDV) 146 ± 59 and 134 ± 53 ml; end-systolic volume (ESV) 64 ± 47 and 59 ± 46 ml; SV 82 ± 29 and 74 ± 28 ml (flow-based 74 ± 30 ml); ejection fraction (EF) 59 ± 16 and 58 ± 17 %; and LVM 141 ± 55 and 159 ± 58 g. Significant differences between the conventional and threshold-based methods were observed in EDV, ESV, and LVM mesurements; SV from threshold-based and flow-based measurements were in agreement (P > 0.05) but were significantly different from conventional analysis (P < 0.05). Excellent inter-observer agreement was observed. Threshold-based LV segmentation provides improved accuracy and faster assessment compared to conventional contour-based methods. • Threshold-based left ventricular segmentation provides time-efficient assessment of left ventricular parameters • The threshold-based method can discriminate between blood and papillary muscles • This method provides improved accuracy compared to aortic flow measurements as a referenceKeywords
This publication has 27 references indexed in Scilit:
- Improving the reproducibility of MR-derived left ventricular volume and function measurements with a semi-automatic threshold-based segmentation algorithmThe International Journal of Cardiovascular Imaging, 2012
- Improved Left Ventricular Mass Quantification With Partial Voxel InterpolationCirculation: Cardiovascular Imaging, 2012
- Unsupervised 4D myocardium segmentation with a Markov Random Field based deformable modelMedical Image Analysis, 2011
- A review of segmentation methods in short axis cardiac MR imagesMedical Image Analysis, 2011
- Image based background magnetic field correction for aortic and pulmonary artery flow measurement using phase contrastJournal of Cardiovascular Magnetic Resonance, 2011
- Flow measurement by cardiovascular magnetic resonance: a multi-centre multi-vendor study of background phase offset errors that can compromise the accuracy of derived regurgitant or shunt flow measurementsJournal of Cardiovascular Magnetic Resonance, 2010
- Automatic image‐driven segmentation of the ventricles in cardiac cine MRIJournal of Magnetic Resonance Imaging, 2008
- Normal human left and right ventricular dimensions for MRI as assessed by turbo gradient echo and steady‐state free precession imaging sequencesJournal of Magnetic Resonance Imaging, 2003
- Multistage hybrid active appearance model matching: segmentation of left and right ventricles in cardiac MR imagesIEEE Transactions on Medical Imaging, 2001
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986