CFD Simulations and Experiments of Flow Fluctuations Around a Steam Control Valve
Authors:
- 11 June 2006
- journal article
- Published by ASME International in Journal of Fluids Engineering
- Vol. 129 (1) , 48-54
Abstract
Under certain opening conditions (partial opening) of a steam control valve, the piping system in a power plant occasionally experiences large vibrations. To understand the valve instability that is responsible for such vibrations, detailed experiments and CFD calculations were performed. As a result of these investigations, it was found that under the middle-opening (partial opening) condition, a complex three-dimensional (3D) flow structure (valve-attached flow) sets up in the valve region leading to a high pressure region on a part of the valve body. As this region rotates circumferentially, it causes a cyclic asymmetric side load on the valve body, which is considered to be the cause of the vibrations.Keywords
This publication has 5 references indexed in Scilit:
- Acoustic Fatigue of a Steam Dump Pipe System Excited by Valve NoiseJournal of Pressure Vessel Technology, 2001
- Determination of Peak Internal Sound Frequency Generated by Throttling Valves for the Calculation of Pipe Transmission LossesNoise Control Engineering Journal, 1991
- Lower-upper Symmetric-Gauss-Seidel method for the Euler and Navier-Stokes equationsAIAA Journal, 1988
- A Theoretically Based Valve Noise Prediction Method for Compressible FluidsJournal of Vibration and Acoustics, 1986
- Coefficients and Factors Relating to the Aerodynamic Sound Level Generated by Throttling ValvesNoise Control Engineering Journal, 1984