Shock-tube study of high-pressure H_2O spectroscopy
Authors:
- 20 November 1999
- journal article
- Published by Optica Publishing Group in Applied Optics
- Vol. 38 (33) , 6942-6950
Abstract
Water-vapor absorption features near 7117, 7185, and 7462 cm-1 were probed at pressures to 65 atm (1 atm = 760 Torr) and temperatures to 1800 K in shock-heated mixtures of H2O in N2 and Ar with a diode-laser source. Calculated absorbances based on Voigt line shapes and measured line parameters were in good agreement, within 10%, with measured absorbances at 7185.4 and 7117.4 cm-1. We obtained temperature-dependent N2 and Ar shift parameters for H2O absorption features by shifting the calculated spectra to match the recorded absorption scan. Absorbance simulations based on line parameters from HITRAN and HITEMP were found to be similar over the range of temperatures 600–1800 K and were within 25% of the measurements. The combined use of Toth’s [Appl. Opt. 36, 4851 (1994)] line positions and strengths and HITRAN broadening parameters resulted in calculated absorption coefficients that were within 15% of the measurements at all three probed wavelengths.Keywords
This publication has 21 references indexed in Scilit:
- Diode laser measurements of line strengths and self-broadening parameters of water vapor between 300 and 1000K near 1.31μmJournal of Quantitative Spectroscopy and Radiative Transfer, 1998
- Design of a diode-laser sensor to monitor water vapor in high-pressure combustion gasesApplied Optics, 1997
- Scanned- and fixed-wavelength absorption diagnostics for combustion measurements using multiplexed diode lasersAIAA Journal, 1996
- Ultrasensitive dual-beam absorption and gain spectroscopy: applications for near-infrared and visible diode laser sensorsApplied Optics, 1995
- Multiplexed diode-laser sensor system for simultaneous H_2O, O_2, and temperature measurementsOptics Letters, 1994
- The GEISA data bank in 1993: A PC/AT compatible computers' new versionJournal of Quantitative Spectroscopy and Radiative Transfer, 1994
- Dual diode-laser fiber-optic diagnostic for water-vapor measurementsOptics Letters, 1994
- Diode-laser absorption technique for simultaneous measurements of multiple gasdynamic parameters in high-speed flows containing water vaporApplied Optics, 1994
- Absorption measurements of water-vapor concentration, temperature, and line-shape parameters using a tunable InGaAsP diode laserApplied Optics, 1993
- The HITRAN molecular database: Editions of 1991 and 1992Journal of Quantitative Spectroscopy and Radiative Transfer, 1992