Early biomechanical keratoconus pattern measured with an ocular response analyzer: Curve analysis
Authors:
- David TouboulDTDavid Touboul
- Antoine BénardABAntoine Bénard
- Ashraf M. MahmoudAMAshraf M. Mahmoud
- Anne GalloisAGAnne Gallois
- Joseph ColinJCJoseph Colin
- Cynthia J. RobertsCRCynthia J. Roberts
- 1 December 2011
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 37 (12) , 2144-2150
Abstract
To estimate the ability of the Ocular Response Analyzer parameters to aid in the diagnosis of keratoconus in pre-laser in situ keratomileusis (LASIK) patients. Department of Ophthalmology, Bordeaux 2 University, Bordeaux Cedex, France. Evaluation of diagnostic test. This study compared eyes with mild stages of keratoconus (study group) with preoperative eyes that later had LASIK (control group). Corneas with a central thickness within 500 to 600 μm were targeted. The biomechanical measurements were acquired, and 12 parameters were analyzed after extraction from the signal data. The study group comprised 103 eyes and the control group, 97 eyes. The mean corneal hysteresis (CH) was 9.2 mm Hg in study eyes and 10.1 mm Hg in control eyes and the mean corneal resistance factor (CRF), 8.9 mm Hg and 10.6 mm Hg, respectively. For a threshold of 9.6, CH had a sensitivity of 66% with a specificity of 67%. For a threshold of 9.7, the CRF had a sensitivity of 72% and a specificity of 77%. For 6 biomechanical parameters, the probability that a patient would present with keratoconus was 3 in 1000 if 1 parameter was over the chosen threshold. If 1 of 6 parameters were over a chosen threshold, the probability that a patient would present with keratoconus would be almost 3 in 1000 instead of 9 in 1000 in a LASIK surgery cohort. Despite low sensitivity and specificity, some parameters provided by the corneal analyzer offered high negative likelihood ratios and deserve more study with bigger samples.Keywords
This publication has 23 references indexed in Scilit:
- Ocular Response Analyzer Measurements in Keratoconus with Normal Central Corneal Thickness Compared with Matched Normal Control EyesJournal of Refractive Surgery, 2011
- Ocular Response Analyzer and Goldmann Applanation TonometryJournal of Glaucoma, 2010
- Biomechanical and Tomographic Analysis of Unilateral KeratoconusJournal of Refractive Surgery, 2010
- Evaluation of the Intraocular Pressure Measured with the Ocular Response AnalyzerCurrent Eye Research, 2010
- Corneal hysteresis measured with the Ocular Response Analyzer® in normal and glaucomatous eyesActa Ophthalmologica, 2010
- Effect of Aging on Corneal Biomechanical Parameters Using the Ocular Response AnalyzerJournal of Refractive Surgery, 2009
- A Nonlinear Anisotropic Viscoelastic Model for the Tensile Behavior of the Corneal StromaJournal of Biomechanical Engineering, 2008
- Corneal biomechanical properties in normal, post-laser in situ keratomileusis, and keratoconic eyesJournal of Cataract & Refractive Surgery, 2007
- Post-laser in-situ keratomileusis ectasia: current understanding and future directionsCurrent Opinion in Ophthalmology, 2006
- Influence of corneal biomechanical properties on intraocular pressure measurementJournal of Cataract & Refractive Surgery, 2005