Mechanical and Biological Advantages of a Tri-Oval Implant Design
Open Access
- 28 March 2019
- journal article
- research article
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 8 (4) , 427
Abstract
Of all geometric shapes, a tri-oval one may be the strongest because of its capacity to bear large loads with neither rotation nor deformation. Here, we modified the external shape of a dental implant from circular to tri-oval, aiming to create a combination of high strain and low strain peri-implant environment that would ensure both primary implant stability and rapid osseointegration, respectively. Using in vivo mouse models, we tested the effects of this geometric alteration on implant survival and osseointegration over time. The maxima regions of tri-oval implants provided superior primary stability without increasing insertion torque. The minima regions of tri-oval implants presented low compressive strain and significantly less osteocyte apoptosis, which led to minimal bone resorption compared to the round implants. The rate of new bone accrual was also faster around the tri-oval implants. We further subjected both round and tri-oval implants to occlusal loading immediately after placement. In contrast to the round implants that exhibited a significant dip in stability that eventually led to their failure, the tri-oval implants maintained their stability throughout the osseointegration period. Collectively, these multiscale biomechanical analyses demonstrated the superior in vivo performance of the tri-oval implant design.Keywords
Funding Information
- National Institutes of Health (DE 024000)
- National Natural Science Foundation of China (81801019)
- China Postdoctoral Science Foundation (2018M640929)
- Nobel Biocare Services AG (2015-1400)
This publication has 38 references indexed in Scilit:
- Primary cilia act as mechanosensors during bone healing around an implantMedical Engineering & Physics, 2012
- Use of micro-CT-based finite element analysis to accurately quantify peri-implant bone strains: a validation in rat tibiaeBiomechanics and Modeling in Mechanobiology, 2011
- Guidelines for assessment of bone microstructure in rodents using micro–computed tomographyJournal of Bone and Mineral Research, 2010
- Is the osseointegration of immediately and delayed loaded implants the same?—comparison of the implant stability during a 3‐month healing period in a prospective studyClinical Oral Implants Research, 2009
- Elastic properties and apparent density of human edentulous maxilla and mandibleInternational Journal of Oral and Maxillofacial Surgery, 2009
- Effect of mechanical stimuli on skeletal regeneration around implantsBone, 2007
- Tissue Response to Titanium Implants in the Rat Maxilla: Ultrastructural and Histochemical Observations of the Bone‐Titanium InterfaceJournal of Periodontology, 2000
- A comparison between cutting torque and resonance frequency measurements of maxillary implantsInternational Journal of Oral and Maxillofacial Surgery, 1999
- Stability measurements of one-stage Brånemark implants during healing in mandiblesInternational Journal of Oral and Maxillofacial Surgery, 1999
- Resonance frequency measurements of implant stability in viva. A cross‐sectional and longitudinal study of resonance frequency measurements on implants in the edentulous and partially dentate maxilla.Clinical Oral Implants Research, 1997