Evaluation of the deformation and corresponding dosimetric implications in prostate cancer treatment
Authors:
- 3 August 2012
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 57 (17) , 5361-5379
Abstract
The cone-beam computed tomography (CBCT) imaging modality is an integral component of image-guided adaptive radiation therapy (IGART), which uses patient-specific dynamic/temporal information for potential treatment plan modification. In this study, an offline process for the integral component IGART framework has been implemented that consists of deformable image registration (DIR) and its validation, dose reconstruction, dose accumulation and dose verification. This study compares the differences between planned and estimated delivered doses under an IGART framework of five patients undergoing prostate cancer radiation therapy. The dose calculation accuracy on CBCT was verified by measurements made in a Rando pelvic phantom. The accuracy of DIR on patient image sets was evaluated in three ways: landmark matching with fiducial markers, visual image evaluation and unbalanced energy (UE); UE has been previously demonstrated to be a feasible method for the validation of DIR accuracy at a voxel level. The dose calculated on each CBCT image set was reconstructed and accumulated over all fractions to reflect the 'actual dose' delivered to the patient. The deformably accumulated (delivered) plans were then compared to the original (static) plans to evaluate tumor and normal tissue dose discrepancies. The results support the utility of adaptive planning, which can be used to fully elucidate the dosimetric impact based on the simulated delivered dose to achieve the desired tumor control and normal tissue sparing, which may be of particular importance in the context of hypofractionated radiotherapy regimens.Keywords
This publication has 32 references indexed in Scilit:
- A study on adaptive IMRT treatment planning using kV cone-beam CTRadiotherapy and Oncology, 2007
- FEM-based evaluation of deformable image registration for radiation therapyPhysics in Medicine & Biology, 2007
- Formulating adaptive radiation therapy (ART) treatment planning into a closed-loop control frameworkPhysics in Medicine & Biology, 2007
- Use of Individual Fraction Size Data from 3756 Patients to Directly Determine the α/β Ratio of Prostate CancerInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2007
- An Adaptive Off-Line Procedure for Radiotherapy of Prostate CancerInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2007
- Investigation of bladder dose and volume factors influencing late urinary toxicity after external beam radiotherapy for prostate cancerInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2007
- Multi-institutional clinical experience with the Calypso System in localization and continuous, real-time monitoring of the prostate gland during external radiotherapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2007
- Evaluation of on-board kV cone beam CT (CBCT)-based dose calculationPhysics in Medicine & Biology, 2007
- Dosimetric feasibility of cone-beam CT-based treatment planning compared to CT-based treatment planningInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2006
- Dose-Response in Radiotherapy for Localized Prostate Cancer: Results of the Dutch Multicenter Randomized Phase III Trial Comparing 68 Gy of Radiotherapy With 78 GyJournal of Clinical Oncology, 2006