Anatomic Customization of Root-Analog Dental Implants With Cone-Beam CT and CAD/CAM Fabrication: A Cadaver-Based Pilot Evaluation
Authors:
- 1 February 2018
- journal article
- research article
- Published by American Academy of Implant Dentistry in Journal of Oral Implantology
- Vol. 44 (1) , 15-26
Abstract
Existing root-analog dental implant systems have no standardized protocols regarding retentive design, surface manipulation, or prosthetic attachment design relative to the site's unique anatomy. Historically, existing systems made those design choices arbitrarily. For this report, strategies were developed that deliberately reference the adjacent anatomy, implant and restorable path of draw, and bone density for implant and retentive design. For proof of concept, dentate arches from human cadavers were scanned using cone-beam computed tomography and then digitally modeled. Teeth of interest were virtually extracted and manipulated via computer-aided design to generate root-analog implants from zirconium. We created a stepwise protocol for analyzing and developing the implant sites, implant design and retention, and prosthetic emergence and connection all from the pre-op cone-beam data. Root-analog implants were placed at the time of extraction and examined radiographically and mechanically concerning ideal fit and stability. This study provides proof of concept that retentive root-analog implants can be produced from cone-beam data while improving fit, retention, safety, esthetics, and restorability when compared to the existing protocols. These advancements may provide the critical steps necessary for clinical relevance and success of immediately placed root-analog implants. Additional studies are necessary to validate the model prior to clinical trial.Keywords
This publication has 26 references indexed in Scilit:
- Immediate, single stage, truly anatomic zirconia implant in lower molar replacement: A case report with 2.5 years follow-upInternational Journal of Oral and Maxillofacial Surgery, 2011
- Alumina‐reinforced zirconia implants: survival rate and fracture strength in a masticatory simulation trialClinical Oral Implants Research, 2010
- Immediate, non-submerged, root-analogue zirconia implants placed into single-rooted extraction sockets: 2-year follow-up of a clinical studyInternational Journal of Oral and Maxillofacial Surgery, 2009
- Cone-beam computerized tomography (CBCT) imaging of the oral and maxillofacial region: A systematic review of the literatureInternational Journal of Oral and Maxillofacial Surgery, 2009
- Immediate, non-submerged, root-analogue zirconia implant in single tooth replacementInternational Journal of Oral and Maxillofacial Surgery, 2008
- Long‐Term Evaluation of Hollow Screw and Hollow Cylinder Dental Implants: Clinical and Radiographic Results After 10 YearsJournal of Periodontology, 2006
- Custom‐made root analogue titanium implants placed into extraction sockets. An experimental study in monkeys.Clinical Oral Implants Research, 1997
- Influence of initial implant mobility on the integration of titanium implants. An experimental study in rabbits.Clinical Oral Implants Research, 1996
- Healing‐in of root analogue titanium implants placed in extraction sockets. An experimental study in the beagle dog.Clinical Oral Implants Research, 1992
- The dental polymer implant conceptThe Journal of Prosthetic Dentistry, 1969