Sensitivity and specificity of the nickel spot (dimethylglyoxime) test
- 23 April 2010
- journal article
- research article
- Published by Wiley in Contact Dermatitis
- Vol. 62 (5) , 279-288
Abstract
Background: The accuracy of the dimethylglyoxime (DMG) nickel spot test has been questioned because of false negative and positive test reactions. The EN 1811, a European standard reference method developed by the European Committee for Standardization (CEN), is fine‐tuned to estimate nickel release around the limit value of the EU Nickel Directive from products intended to come into direct and prolonged skin contact. Because assessments according to EN 1811 are expensive to perform, time consuming, and may destruct the test item, it should be of great value to know the accuracy of the DMG screening test. Objectives: To evaluate the sensitivity and specificity of the DMG test. Methods: DMG spot testing, chemical analysis according to the EN 1811 reference method, and X‐ray fluorescence spectroscopy (XRF) were performed concomitantly on 96 metallic components from earrings recently purchased in San Francisco. Results: The sensitivity of the DMG test was 59.3% and the specificity was 97.5% based on DMG‐test results and nickel release concentrations determined by the EN 1811 reference method. Conclusions: The DMG test has a high specificity but a modest sensitivity. It may serve well for screening purposes. Past exposure studies may have underestimated nickel release from consumer items.Keywords
This publication has 35 references indexed in Scilit:
- Children’s clothing fasteners as a potential source of exposure to releasable nickel ionsContact Dermatitis, 2009
- The outcome of dimethylglyoxime testing in a sample of cell phones in DenmarkContact Dermatitis, 2008
- Deposition of nickel, chromium, and cobalt on the skin in some occupations – assessment by acid wipe samplingContact Dermatitis, 2008
- A general population from Thailand: incidence of common allergens with emphasis on para‐phenylenediamineClinical & Experimental Allergy, 2007
- Dose per unit area - a study of elicitation of nickel allergyContact Dermatitis, 2007
- The European standard series in 9 European countries, 2002/2003 – First results of the European Surveillance System on Contact AllergiesContact Dermatitis, 2005
- Properties of the magnetic field in the coronal holes in solar cycle 23Proceedings of the International Astronomical Union, 2004
- Periumbilical Allergic Contact Dermatitis: Blue Jeans or Belt Buckles?Pediatric Dermatology, 2004
- Effects of repeated skin exposure to low nickel concentrations: a model for allergic contact dermatitis to nickel on the handsBritish Journal of Dermatology, 1999
- Regulation of nickel exposure in DenmarkContact Dermatitis, 1990