CryoFIB milling large tissue samples for cryo-electron tomography
Open Access
- 11 April 2023
- journal article
- research article
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-12
Abstract
Cryo-electron tomography (cryoET) is a powerful tool for exploring the molecular structure of large organisms. However, technical challenges still limit cryoET applications on large samples. In particular, localization and cutting out objects of interest from a large tissue sample are still difficult steps. In this study, we report a sample thinning strategy and workflow for tissue samples based on cryo-focused ion beam (cryoFIB) milling. This workflow provides a full solution for isolating objects of interest by starting from a millimeter-sized tissue sample and ending with hundred-nanometer-thin lamellae. The workflow involves sample fixation, pre-sectioning, a two-step milling strategy, and localization of the object of interest using cellular secondary electron imaging (CSEI). The milling strategy consists of two steps, a coarse milling step to improve the milling efficiency, followed by a fine milling step. The two-step milling creates a furrow–ridge structure with an additional conductive Pt layer to reduce the beam-induced charging issue. CSEI is highlighted in the workflow, which provides on-the-fly localization during cryoFIB milling. Tests of the complete workflow were conducted to demonstrate the high efficiency and high feasibility of the proposed method.Keywords
All Related Versions
This publication has 39 references indexed in Scilit:
- Paraxial charge compensator for electron cryomicroscopyUltramicroscopy, 2012
- Correlative microscopy: Bridging the gap between fluorescence light microscopy and cryo-electron tomographyJournal of Structural Biology, 2007
- Focused-ion-beam thinning of frozen-hydrated biological specimens for cryo-electron microscopyNature Methods, 2007
- Automated electron microscope tomography using robust prediction of specimen movementsJournal of Structural Biology, 2005
- Cutting artefacts and cutting process in vitreous sections for cryo-electron microscopyJournal of Structural Biology, 2005
- Spontaneous recovery from micronodular cirrhosis: Evidence for incomplete resolution associated with matrix cross-linking☆Gastroenterology, 2004
- Determination of the inelastic mean free path in ice by examination of tilted vesicles and automated most probable loss imagingUltramicroscopy, 1996
- Computer Visualization of Three-Dimensional Image Data Using IMODJournal of Structural Biology, 1996
- Vitrification of articular cartilage by high‐pressure freezingJournal of Microscopy, 1995
- Theoretical and practical aspects of glutaraldehyde fixationJournal of Molecular Histology, 1972