Evaluation of a Body-Worn Sensor System to Measure Physical Activity in Older People With Impaired Function
Authors:
- Kristin TaraldsenKTKristin Taraldsen
- Torunn AskimTATorunn Askim
- Olav SletvoldOSOlav Sletvold
- Elin Kristin EinarsenEEElin Kristin Einarsen
- Karianne Grüner BjåstadKBKarianne Grüner Bjåstad
- Bent IndredavikBIBent Indredavik
- Jorunn Laegdheim HelbostadJHJorunn Laegdheim Helbostad
- 1 February 2011
- journal article
- research article
- Published by Oxford University Press (OUP) in Physical Therapy
- Vol. 91 (2) , 277-285
Abstract
Background There is limited information on reliable and valid measures of physical activity in older people with impaired function. Objective This study was conducted to compare the accuracy of single-axis accelerometers in recognizing postures and transitions and step counting with the accuracy of video recordings in people with stroke (n=14), older inpatients (n=14), people with hip fracture (n=8), and a reference group of 10 adults who were healthy. Design This was a cross-sectional study, evaluating the concurrent validity of small body-worn accelerometers against video observations as the criterion measure. Methods Activity data were collected from 3 sensors (activPAL) attached to the thighs and the sternum and from registration of the same activities from video recordings. Participants performed a test protocol of in-bed, transfer, and walking activities. Results The sensor system was highly accurate in classifying lying, sitting, and standing positions (100%) and in recognizing transitions from lying to sitting positions and from sitting to standing positions (100%). Placement of a sensor on the nonaffected leg resulted in less underestimation of step counts than placement on the affected leg. Still, the sensor system underestimated step counts during walking, especially at slow walking speeds (≤0.47 m/s) (limits of agreement=−2.01 to 16.54, absolute percent error=40.31). Limitations The study was performed in a controlled setting and not during the natural performance of activities. Conclusions The activPAL sensor system provides valid measures of postures and transitions in older people with impaired walking ability. Step counting needs to be improved for the sensor system to be acceptable for this population, especially at slow walking speeds.Keywords
This publication has 20 references indexed in Scilit:
- An adaptive Kalman-based Bayes estimation technique to classify locomotor activities in young and elderly adults through accelerometersMedical Engineering & Physics, 2010
- Physical Activity, Function, and Longevity Among the Very OldArchives of internal medicine (1960), 2009
- The Sensitivity and Specificity of an Activity Monitor in Detecting Functional Activities in Young People With Cerebral PalsyArchives of Physical Medicine and Rehabilitation, 2009
- Wearable systems for monitoring mobility-related activities in older people: a systematic reviewClinical Rehabilitation, 2008
- Activity-Monitor Accuracy in Measuring Step Number and Cadence in Community-Dwelling Older AdultsJournal of Aging and Physical Activity, 2008
- Comparison of the performance of the activPAL™ Professional physical activity logger to a discrete accelerometer-based activity monitorMedical Engineering & Physics, 2006
- The validation of a novel activity monitor in the measurement of posture and motion during everyday activitiesBritish Journal of Sports Medicine, 2006
- The validity and reliability of a novel activity monitor as a measure of walkingBritish Journal of Sports Medicine, 2006
- Treatment in a Combined Acute and Rehabilitation Stroke UnitStroke, 1999
- Energy requirements and physical activity in free-living older women and men: a doubly labeled water studyJournal of Applied Physiology, 1998