Lung Ultrasound in Coronary Care Unit, an Important Diagnostic Tool for Concomitant Pneumonia
Authors:
- Costantino MancusiCostantino Mancusi
- Ilaria FucileIFIlaria Fucile
- Paola GargiuloPGPaola Gargiulo
- Mariangela MoscaMMMariangela Mosca
- Biagio MigliaccioBMBiagio Migliaccio
- Christian BasileCBChristian Basile
- Giuseppe GargiuloGiuseppe Gargiulo
- Ciro SantoroCSCiro Santoro
- Carmine MoriscoCMCarmine Morisco
- Nicola De LucaNLNicola De Luca
- Giovanni EspositoGEGiovanni Esposito
Open Access
- 7 December 2022
- journal article
- research article
- Published by MDPI AG in Diagnostics
- Vol. 12 (12) , 3082
Abstract
Background: In the setting of a coronary care unit (CCU), the early detection of pneumonia is of paramount important to prevent severe complications. This study was designed aiming to evaluate the diagnostic accuracy of lung ultrasound (LUS) in the detection of pneumonia and compared with chest X-ray (CXR). Method: We enrolled 110 consecutive patients admitted to the CCU of Federico II University Hospital. Each patient underwent CXR and bedside LUS on admission. The final diagnosis (pneumonia vs. no pneumonia) was established by another clinician reviewing clinical and laboratory data independent of LUS results and possibly prescribing chest contrast-enhanced CT (n = 34). Results: The mean age was 70 ± 11 years old, and 68% were males. Pneumonia was clinically diagnosed in 26 (23%) patients. LUS was positive for pneumonia in 24 patients (sensitivity 92%, specificity 81%). Chest radiography was positive for pneumonia in nine patients (sensitivity 43%, specificity 95%). Using CT scan as a reference, LUS exhibited 92% sensitivity and a specificity of 96%. In ROC curve analysis, the diagnostic accuracy of CXR and LUS for the diagnosis of pneumonia was 0.86 (95% CI 0.77–0.94), which was higher than CXR 0.68 (95% CI 0.55–0.84), p < 0.05. Conclusion: Based on the findings of the present study, the accuracy of LUS in the detection of pneumonia was significantly higher than chest X-ray with comparable sensibility to CT scan.Keywords
This publication has 30 references indexed in Scilit:
- Lung ultrasound for diagnosis of pneumonia in emergency departmentInternal and Emergency Medicine, 2015
- Lung Ultrasound-Implemented Diagnosis of Acute Decompensated Heart Failure in the EDChest, 2015
- Accuracy of lung ultrasound for the diagnosis of consolidations when compared to chest computed tomographyThe American Journal of Emergency Medicine, 2015
- Point-of-care Ultrasonography for the Diagnosis of Acute Cardiogenic Pulmonary Edema in Patients Presenting With Acute Dyspnea: A Systematic Review and Meta-analysisAcademic Emergency Medicine, 2014
- Lung ultrasonography: an effective way to diagnose community-acquired pneumoniaEmergency Medicine Journal, 2014
- Lung ultrasound for the diagnosis of pneumonia in adults: a systematic review and meta-analysisRespiratory Research, 2014
- High discordance of chest x-ray and computed tomography for detection of pulmonary opacities in ED patients: implications for diagnosing pneumoniaThe American Journal of Emergency Medicine, 2013
- Lung ultrasound: a new tool for the cardiologistCardiovascular Ultrasound, 2011
- Emergency Thoracic Ultrasound in the Differentiation of the Etiology of Shortness of Breath (ETUDES): Sonographic B-lines and N-terminal Pro-brain-type Natriuretic Peptide in Diagnosing Congestive Heart FailureAcademic Emergency Medicine, 2009
- Ultrasound Lung Comets for the Differential Diagnosis of Acute Cardiogenic Dyspnoea: A Comparison with Natriuretic PeptidesEuropean Journal of Heart Failure, 2008