Are wearable heart rate measurements accurate to estimate aerobic energy cost during low-intensity resistance exercise?
Open Access
- 22 August 2019
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 14 (8) , e0221284
Abstract
The aim of the present study was to assess the accuracy of heart rate to estimate energy cost during eight resistance exercises performed at low intensities: half squat, 45° inclined leg press, leg extension, horizontal bench press, 45° inclined bench press, lat pull down, triceps extension and biceps curl. 56 males (27.5 ± 4.9 years, 1.78 ± 0.06 m height, 78.67 ± 10.7 kg body mass and 11.4 ± 4.1% estimated body fat) were randomly divided into four groups of 14 subjects each. Two exercises were randomly assigned to each group and subjects performed four bouts of 4-min constant-intensity at each assigned exercise: 12%, 16%, 20% and 24% 1-RM. Exercise and intensity order were random. Each subject performed no more than 2 bouts in the same testing session. A minimum recovery of 24h was kept between sessions. During testing VO2 was measured with Cosmed K4b2 and heart rate was measured with Polar V800 monitor. Energy cost was calculated from mean VO2 during the last 30-s of each bout by using the energy equivalent 1 ml O2 = 5 calorie. Linear regressions with heart rate as predictor and energy cost as dependent variable were build using mean data from all subjects. Robustness of the regression lines was given by the scatter around the regression line (Sy.x) and Bland-Altman plots confirmed the agreement between measured and estimated energy costs. Significance level was set at p≤0.05. The regressions between heart rate and energy cost in the eight exercises were significant (py.x = 0,48 kcal·min-1), 45° inclined leg press (Sy.x = 0,54 kcal·min-1), leg extension (Sy.x = 0,59 kcal·min-1), horizontal bench press (Sy.x = 0,47 kcal·min-1), 45° inclined bench press (Sy.x = 0,54 kcal·min-1), lat pull down (Sy.x = 0,28 kcal·min-1), triceps extension (Sy.x = 0,08 kcal·min-1) and biceps curl (Sy.x = 0,13 kcal·min-1). We conclude that during low-intensity resistance exercises it is possible to estimate aerobic energy cost by wearable heart rate monitors with errors below 10% in healthy young trained males.Keywords
Funding Information
- NORTE 2020 (NanoSTIMA, NORTE-01-0145- FEDER-000016)
This publication has 14 references indexed in Scilit:
- Congruent Validity and Reliability of Two Metabolic Systems to Measure Resting Metabolic RateInternational Journal of Sports Medicine, 2015
- Energy Expenditure and Fitness Response Following Once Weekly Hill Climbing at Low AltitudeInternational Journal of Sports Medicine, 2015
- Mechanical Load and Physiological Responses of Four Different Resistance Training Methods in Bench Press ExerciseJournal of Strength & Conditioning Research, 2013
- Quantity and Quality of Exercise for Developing and Maintaining Cardiorespiratory, Musculoskeletal, and Neuromotor Fitness in Apparently Healthy AdultsMedicine & Science in Sports & Exercise, 2011
- Is the VO2 slow component in heavy arm-cranking exercise associated with recruitment of type II muscle fibers as assessed by an increase in surface EMG?Applied Physiology, Nutrition, and Metabolism, 2006
- Accuracy of Polar S410 Heart Rate Monitor to Estimate Energy Cost of ExerciseMedicine & Science in Sports & Exercise, 2004
- Oxygen uptake kinetics during high-intensity arm and leg exerciseRespiratory Physiology & Neurobiology, 2002
- Validation of the COSMED K4 b2 Portable Metabolic SystemInternational Journal of Sports Medicine, 2001
- The relationship between heart rate and oxygen uptake during non-steady state exerciseErgonomics, 2000
- Generalized equations for predicting body density of menBritish Journal of Nutrition, 1978