Attenuation in trabecular bone: A comparison between numerical simulation and experimental results in human femur
- 1 October 2007
- journal article
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 122 (4) , 2469-2475
Abstract
Numerical simulations (finite-difference time domain) are compared to experimental results of ultrasound wave propagation through human trabecular bones. Three-dimensional high-resolution microcomputed tomography reconstructions served as input geometry for the simulation. The numerical simulation took into account scattering, but not absorption. Simulated and experimental values of the attenuation coefficients (α, dB/cm) and the normalized broadband ultrasound attenuation (nBUA, dB/cm/MHz) were measured and compared on a set of 28 samples. While experimental and simulated nBUA values were highly correlated (R2=0.83), and showed a similar dependence with bone volume fraction, the simulation correctly predicted experimental nBUA values only for low bone volume fraction (BV/TV). Attenuation coefficients were underestimated by the simulation. The absolute difference between experimental and simulated α values increased with both BV/TV and frequency. As a function of frequency, the relative difference between experimental and simulated α values decreased from 60% around 400kHz to 30% around 1.2MHz. Under the assumption that the observed discrepancy expresses the effect of the absorption, our results suggests that nBUA and its dependence on BV/TV can be mostly explained by scattering, and that the relative contribution of scattering to α increases with frequency, becoming predominant (>50 %) over absorption for frequencies above 600kHz.Keywords
This publication has 24 references indexed in Scilit:
- Variation of Ultrasonic Parameters With Microstructure and Material Properties of Trabecular Bone: A 3D Model SimulationJournal of Bone and Mineral Research, 2007
- A method for the estimation of femoral bone mineral density from variables of ultrasound transmission through the human femurBone, 2007
- Three-dimensional simulation of ultrasound propagation through trabecular bone structures measured by synchrotron microtomographyPhysics in Medicine & Biology, 2005
- Simulation of ultrasound propagation through bovine cancellous bone using elastic and Biot’s finite-difference time-domain methodsThe Journal of the Acoustical Society of America, 2005
- Ultrasonic wave propagation in human cancellous bone: Application of Biot theoryThe Journal of the Acoustical Society of America, 2004
- Association of Five Quantitative Ultrasound Devices and Bone Densitometry With Osteoporotic Vertebral Fractures in a Population-Based Sample: The OPUS StudyJournal of Bone and Mineral Research, 2004
- Three-dimensional simulations of ultrasonic axial transmission velocity measurement on cortical bone modelsThe Journal of the Acoustical Society of America, 2004
- Ultrasonic characterization of human cancellous bone using transmission and backscatter measurements: relationships to density and microstructureBone, 2002
- Application of the perfectly matched absorbing layer model to the linear elastodynamic problem in anisotropic heterogeneous mediaGeophysics, 2001
- In vitro measurement of the frequency-dependent attenuation in cancellous bone between 0.2 and 2 MHzThe Journal of the Acoustical Society of America, 2000