High Fidelity Virtual Stenting (HiFiVS) for Intracranial Aneurysm Flow Diversion: In Vitro and In Silico
- 20 April 2013
- journal article
- research article
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 41 (10) , 2143-2156
Abstract
A flow diverter (FD) is a flexible, densely braided stent-mesh device placed endoluminally across an intracranial aneurysm to induce its thrombotic occlusion. FD treatment planning using computational virtual stenting and flow simulation requires accurate representation of the expanded FD geometry. We have recently developed a high fidelity virtual stenting (HiFiVS) technique based on finite element analysis to simulate detailed FD deployment processes in patient-specific aneurysms (Ma et al. J. Biomech. 45:2256–2263, 2012). This study tests if HiFiVS simulation can recapitulate real-life FD implantation. We deployed two identical FDs (Pipeline Embolization Device) into phantoms of a wide-necked segmental aneurysm using a clinical push–pull technique with different delivery wire advancements. We then simulated these deployment processes using HiFiVS and compared results against experimental recording. Stepwise comparison shows that the simulations precisely reproduced the FD deployment processes recorded in vitro. The local metal coverage rate and pore density quantifications demonstrated that simulations reproduced detailed FD mesh geometry. These results provide validation of the HiFiVS technique, highlighting its unique capability of accurately representing stent intervention in silico.Keywords
This publication has 34 references indexed in Scilit:
- Flow diversion treatment: intra-aneurismal blood flow velocity and WSS reduction are parameters to predict aneurysm thrombosisActa Neurochirurgica, 2012
- Pipeline embolization device (PED) for neurovascular reconstruction: initial experience in the treatment of 101 intracranial aneurysms and dissectionsNeuroradiology, 2011
- Influence of different computational approaches for stent deployment on cerebral aneurysm haemodynamicsInterface Focus, 2011
- Reply:American Journal of Neuroradiology, 2010
- Association of Hemodynamic Characteristics and Cerebral Aneurysm RuptureAmerican Journal of Neuroradiology, 2010
- Endoluminal Scaffolds for Vascular Reconstruction and Exclusion of Aneurysms From the Cerebral CirculationStroke, 2010
- Alteration of Intraaneurysmal Hemodynamics for Flow Diversion Using Enterprise and Vision StentsWorld Neurosurgery, 2010
- Measurements of Dynamic Viscoelasticity of Poly (vinyl alcohol) Hydrogel for the Development of Blood Vessel BiomodelingJournal of Fluid Science and Technology, 2008
- Delivery and release of nitinol stent in carotid artery and their interactions: A finite element analysisJournal of Biomechanics, 2007
- Validation of CFD Simulations of Cerebral Aneurysms With Implication of Geometric VariationsJournal of Biomechanical Engineering, 2006