Evaluation of static physics performance of the jPET-D4 by Monte Carlo simulations
Authors:
- Tomoyuki HasegawaTHTomoyuki Hasegawa
- Eiji YoshidaEYEiji Yoshida
- Ayako KobayashiAKAyako Kobayashi
- Kengo ShibuyaKSKengo Shibuya
- Fumihiko NishikidoFNFumihiko Nishikido
- Tetsuya KobayashiTKTetsuya Kobayashi
- Mikio SugaMSMikio Suga
- Taiga YamayaTYTaiga Yamaya
- Keishi KitamuraKKKeishi Kitamura
- Koichi MaruyamaKMKoichi Maruyama
- Hideo MurayamaHMHideo Murayama
- 18 December 2006
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 52 (1) , 213-230
Abstract
The jPET-D4 is the first PET scanner to introduce a unique four-layer depth-of-interaction (DOI) detector scheme in order to achieve high sensitivity and uniform high spatial resolution. This paper compares measurement and Monte Carlo simulation results of the static physics performance of this prototype research PET scanner. Measurement results include single and coincidence energy spectra, point and line source sensitivities, axial sensitivity profile (slice profile) and scatter fraction. We use GATE (Geant4 application for tomographic emission) as a Monte Carlo radiation transport model. Experimental results are reproduced well by the simulation model with reasonable assumptions on characteristic responses of the DOI detectors. In a previous study, the jPET-D4 was shown to provide a uniform spatial resolution as good as 3 mm (FHWM). In the present study, we demonstrate that a high sensitivity, 11.3 +/- 0.5%, is provided at the FOV centre. However, about three-fourths of this sensitivity is related to multiple-crystal events, for which some misidentification of the crystal cannot be avoided. Therefore, it is crucial to develop a more efficient way to identify the crystal of interaction and to reduce misidentification in order to make use of these high performance values simultaneously. We expect that effective sensitivity can be improved by replacing the GSO crystals with more absorptive crystals such as BGO and LSO. The results we describe here are essential to take full advantage of the next generation PET systems that have DOI recognition capability.Keywords
This publication has 28 references indexed in Scilit:
- Preliminary evaluation of four-layer BGO DOI-detector for PETIEEE Transactions on Nuclear Science, 2006
- Performance of a PET Detector With a 256ch Flat Panel PS-PMTIEEE Transactions on Nuclear Science, 2004
- On-clock non-paralyzable count-loss modelPhysics in Medicine & Biology, 2004
- The use of molecular sieves to produce point sources of radioactivityPhysics in Medicine & Biology, 2004
- Geant4—a simulation toolkitNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2003
- A depth of interaction detector for PET with GSO crystals doped with different amounts of CeIEEE Transactions on Nuclear Science, 2002
- A prototype axial shield for use in 3D whole-body PETIEEE Transactions on Nuclear Science, 2001
- ROOT — An object oriented data analysis frameworkNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1997
- Cerium doped GSO scintillators and its application to position sensitive detectorsIEEE Transactions on Nuclear Science, 1989
- An analysis of some of the physical aspects of positron transaxial tomographyComputers in Biology and Medicine, 1976