Regional lung function determined by electrical impedance tomography during bronchodilator reversibility testing in patients with asthma
- 20 May 2016
- journal article
- Published by IOP Publishing in Physiological Measurement
- Vol. 37 (6) , 698-712
Abstract
The measurement of rapid regional lung volume changes by electrical impedance tomography (EIT) could determine regional lung function in patients with obstructive lung diseases during pulmonary function testing (PFT). EIT examinations carried out before and after bronchodilator reversibility testing could detect the presence of spatial and temporal ventilation heterogeneities and analyse their changes in response to inhaled bronchodilator on the regional level. We examined seven patients suffering from chronic asthma (49 ± 19 years, mean age ± SD) using EIT at a scan rate of 33 images s −1 during tidal breathing and PFT with forced full expiration. The patients were studied before and 5, 10 and 20 min after bronchodilator inhalation. Seven age- and sex-matched human subjects with no lung disease history served as a control study group. The spatial heterogeneity of lung function measures was quantified by the global inhomogeneity indices calculated from the pixel values of tidal volume, forced expiratory volume in one second (FEV 1 ), forced vital capacity (FVC), peak flow and forced expiratory flow between 25% and 75% of FVC as well as histograms of pixel FEV 1 /FVC values. Temporal heterogeneity was assessed using the pixel values of expiration times needed to exhale 75% and 90% of pixel FVC. Regional lung function was more homogeneous in the healthy subjects than in the patients with asthma. Spatial and temporal ventilation distribution improved in the patients with asthma after the bronchodilator administration as evidenced mainly by the histograms of pixel FEV 1 /FVC values and pixel expiration times. The examination of regional lung function using EIT enables the assessment of spatial and temporal heterogeneity of ventilation distribution during bronchodilator reversibility testing. EIT may become a new tool in PFT, allowing the estimation of the natural disease progression and therapy effects on the regional and not only global level.Keywords
Funding Information
- European Union 7th Framework Programme on R&D (WELCOME/611223)
This publication has 31 references indexed in Scilit:
- Globally optimal co-segmentation of three-dimensional pulmonary 1H and hyperpolarized 3He MRI with spatial consistence priorMedical Image Analysis, 2015
- Assessment of respiratory system compliance with electrical impedance tomography using a positive end-expiratory pressure wave maneuver during pressure support ventilation: a pilot clinical studyCritical Care, 2014
- Electrical impedance tomography imaging of the cardiopulmonary systemCurrent Opinion in Critical Care, 2014
- Quantification of ventilation distribution in regional lung injury by electrical impedance tomography and xenon computed tomographyPhysiological Measurement, 2013
- Ventilation distribution measured with EIT at varying levels of pressure support and Neurally Adjusted Ventilatory Assist in patients with ALIIntensive Care Medicine, 2013
- GREIT: a unified approach to 2D linear EIT reconstruction of lung imagesPhysiological Measurement, 2009
- Assessment of Differential Lung Function by Electrical Impedance TomographyArchivos de Bronconeumología, 2008
- Distribution of ventilation in young and elderly adults determined by electrical impedance tomographyRespiratory Physiology & Neurobiology, 2004
- Detection of local lung air content by electrical impedance tomography compared with electron beam CTJournal of Applied Physiology, 2002
- Impedance imaging of lung ventilation: do we need to account for chest expansion?IEEE Transactions on Biomedical Engineering, 1996