A Buck Converter Using Auxiliary-Stage With Multiple-Single-Cycle Non-Linear Control (MSCNLC) for Fast Load Transient Response
- 16 September 2024
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems I: Regular Papers
- Vol. 72 (1) , 453-466
Abstract
Recently, digital ICs with high current slewing characteristics and tight supply voltage margin put increasing demand on the supply regulators. In this paper, an augmented DC-DC buck converter consisting of a lower-frequency main converter and a normally-off fast-switching secondary stage operating in parallel is proposed. The main-stage of the converter uses emulated-current-mode hysteretic control. For the auxiliary transient-suppression stage a nonlinear control scheme termed multiple-single-cycle nonlinear control (MSCNLC) is developed. The proposed augmented regulator improves the load transient response without compromising the overall efficiency of the converter, breaking the well-known efficiency vs. dynamic response trade-off. The high power-efficiency main-stage operating at $F_{sw}=$ 500kHz provides the steady-state DC regulation voltage. The auxiliary-stage adopts a small inductor of 100nH and is only activated when load transient events are detected, providing fast load response, minimizing output voltage deviation. The load transient events are detected through an output capacitor charge tracking circuit, which effectively makes the auxiliary-stage a fast Current-Controlled-Current-Source during transient response. The buck converter is designed for $V_{IN}$ $=$ 3V-5.5V, $V_{OUT}$ $=$ 0.5V-1.1V and $I_{LOAD} =$ 0.5A-8A. It is fabricated in 0.18 $\mu $ m BCD process. The measurement results show that with MSCNLC enabled, the undershoot and overshoot is reduced to 27mV and 58mV during the step-up and step-down response with 2.5A load step by a factor of close to 2, respectively. The recovery time is improved by $\sim$ 1.7x.Keywords
Funding Information
- Semiconductor Research Corporation (SRC) and Texas Analog Center of Excellence (2810.042)
This publication has 32 references indexed in Scilit:
- A Quasi-V2 Hysteretic Buck Converter With Adaptive COT Control for Fast DVS and Load-Transient Response in RF ApplicationsIEEE Transactions on Circuits and Systems II: Express Briefs, 2019
- An Auxiliary-Parallel-Inductor-Based Sequence Switching Control to Improve the Load Transient Response of Buck ConvertersIEEE Transactions on Industrial Electronics, 2018
- 0.293-mm2 Fast Transient Response Hysteretic Quasi- $V^{2}$ DC–DC Converter With Area-Efficient Time-Domain-Based Controller in 0.35- $\mu$ m CMOSIEEE Journal of Solid-State Circuits, 2018
- A Four-Phase Buck Converter With Capacitor-Current-Sensor Calibration for Load-Transient-Response Optimization That Reduces Undershoot/Overshoot and Shortens Settling Time to Near Their Theoretical LimitsIEEE Journal of Solid-State Circuits, 2017
- A 6 A, 93% Peak Efficiency, 4-Phase Digitally Synchronized Hysteretic Buck Converter With ±1.5% Frequency and ±3.6% Current-Sharing ErrorIEEE Journal of Solid-State Circuits, 2017
- A Fixed-Frequency Quasi-${\rm V}^{2}$ Hysteretic Buck Converter With PLL-Based Two-Stage Adaptive Window ControlIEEE Transactions on Circuits and Systems I: Regular Papers, 2015
- Classification of Auxiliary Circuit Schemes for Feeding Fast Load Transients in Switching Power SuppliesIEEE Transactions on Circuits and Systems I: Regular Papers, 2013
- Continuous-Time Digital Controller for High-Frequency DC-DC ConvertersIEEE Transactions on Power Electronics, 2008
- A New Digital Control Algorithm to Achieve Optimal Dynamic Performance in DC-to-DC ConvertersIEEE Transactions on Power Electronics, 2007
- A Comparative Study of Boundary Control With First- and Second-Order Switching Surfaces for Buck Converters Operating in DCMIEEE Transactions on Power Electronics, 2007