Treatment of Hemodialysis Graft Pseudoaneurysms with Stent Grafts: Institutional Experience and Review of the Literature
- 29 June 2009
- journal article
- review article
- Published by Georg Thieme Verlag KG in Seminars in Interventional Radiology
- Vol. 26 (02) , 089-095
Abstract
Hemodialysis access grafts are an important component of the treatment of patients with renal failure. Because access sites are limited, maximizing graft lifespan is of major importance to dialysis patients. Pseudoaneurysm formation is a rare, but important complication potentially limiting the longevity of dialysis grafts. With rapidly advancing technology, placement of stent grafts in patients with end-stage renal disease is an important step in prolonging the life of the graft. We conducted a review of the literature regarding stent-graft use for hemodialysis access. In addition, we looked at our experience utilizing the Viabahn® (W. L. Gore & Associates, Newark, DE) stent graft in pseudoaneurysm repair. Our patients achieved primary patency of their grafts for 1, 5, and 9 months, respectively. No complications related to stent-graft implementation have been encountered in six stent-graft implants over the course of 29 months.Keywords
This publication has 20 references indexed in Scilit:
- Endovascular Repair of Hemodialysis Graft-Related Pseudoaneurysm: An Alternative Treatment Strategy in Salvaging Failing Dialysis AccessVascular and Endovascular Surgery, 2008
- Occlusion of a Rapidly Expanding Hemodialysis Graft Pseudoaneurysm with Placement of a Stent GraftSeminars in Interventional Radiology, 2007
- Comparison of SMART Stent Placement for Arteriovenous Graft Salvage versus Successful Graft PTAJournal of Vascular and Interventional Radiology, 2005
- Use of Stent Grafts to Repair Hemodialysis Graft–related PseudoaneurysmsJournal of Vascular and Interventional Radiology, 2005
- Vascular Access in Hemodialysis: Issues, Management, and Emerging ConceptsCardiology Clinics, 2005
- Dialysis Needle Puncture of Wallgrafts Placed in Polytetrafluoroethylene Hemodialysis GraftsJournal of Vascular and Interventional Radiology, 2005
- Nitinol Stents in Hemodialysis AccessJournal of Vascular and Interventional Radiology, 2004
- SMART Stent for Salvage of Hemodialysis Access GraftsJournal of Vascular and Interventional Radiology, 2004
- Using a Covered Stent (Wallgraft) to Treat Pseudoaneurysms of Dialysis Grafts and FistulasAmerican Journal of Roentgenology, 2003
- Quality Improvement Guidelines for Percutaneous Management of the Thrombosed or Dysfunctional Dialysis AccessJournal of Vascular and Interventional Radiology, 1999