Estimating Blood Pressure with a Camera: An Exploratory Study of Ambulatory Patients with Cardiovascular Disease
Authors:
- Theodore CurranTCTheodore Curran
- Chengqian MaCMChengqian Ma
- Xin LiuXLXin Liu
- Daniel McDuffDMDaniel McDuff
- Girish NarayanswamyGNGirish Narayanswamy
- Shwetak PatelSPShwetak Patel
- Eugene YangEYEugene Yang
Preprint
Abstract
Hypertension is a leading cause of morbidity and mortality worldwide. The ability to diagnose and treat hypertension in the ambulatory population is hindered by limited access and poor adherence to current methods of monitoring blood pressure (BP), specifically, cuff-based devices. Remote photoplethysmography (rPPG) evaluates an individual's pulse waveform through a standard camera without physical contact. Cameras are readily available to the majority of the global population via embedded technologies such as smartphones, thus rPPG is a scalable and promising non-invasive method of BP monitoring. The few studies investigating rPPG for BP measurement have excluded high-risk populations, including those with cardiovascular disease (CVD) or its risk factors, as well as subjects in active cardiac arrhythmia. The impact of arrhythmia, like atrial fibrillation, on the prediction of BP using rPPG is currently uncertain. We performed a study to better understand the relationship between rPPG and BP in a real-world sample of ambulatory patients from a cardiology clinic with established CVD or risk factors for CVD. We collected simultaneous rPPG, PPG, BP, ECG, and other vital signs data from 143 subjects while at rest, and used this data plus demographics to train a deep learning model to predict BP. We report that facial rPPG yields a signal that is comparable to finger PPG. Pulse wave analysis (PWA)-based BP estimates on this cohort performed comparably to studies on healthier subjects, and notably, the accuracy of BP prediction in subjects with atrial fibrillation was not inferior to subjects with normal sinus rhythm. In a binary classification task, the rPPG model identified subjects with systolic BP $\geq$ 130 mm Hg with a positive predictive value of 71% (baseline prevalence 48.3%), highlighting the potential of rPPG for hypertension monitoring.
Keywords
All Related Versions
This publication has 22 references indexed in Scilit:
- Key Issues as Wearable Digital Health Technologies Enter Clinical CareThe New England journal of medicine, 2024
- Wearable Digital Health Technologies for Monitoring in Cardiovascular MedicineNew England Journal of Medicine, 2024
- 2023 ESH Guidelines for the management of arterial hypertension The Task Force for the management of arterial hypertension of the European Society of Hypertension: Endorsed by the International Society of Hypertension (ISH) and the European Renal Association (ERA): ErratumJournal Of Hypertension, 2023
- Camera Measurement of Physiological Vital SignsACM Computing Surveys, 2023
- Seeing beneath the skin with computational photographyCommunications of the ACM, 2022
- A Facial-Image-Based Blood Pressure Measurement System Without CalibrationIEEE Transactions on Instrumentation and Measurement, 2022
- A Comparison of Wearable Tonometry, Photoplethysmography, and Electrocardiography for Cuffless Measurement of Blood Pressure in an Ambulatory SettingIEEE Journal of Biomedical and Health Informatics, 2022
- Worldwide trends in hypertension prevalence and progress in treatment and control from 1990 to 2019: a pooled analysis of 1201 population-representative studies with 104 million participantsThe Lancet, 2021
- Smartphone-Based Blood Pressure Measurement Using Transdermal Optical Imaging TechnologyCirculation: Cardiovascular Imaging, 2019
- A survey on signals and systems in ambulatory blood pressure monitoring using pulse transit timePhysiological Measurement, 2015