Collection Efficiency Comparison of N95 Respirators Saturated with Artificial Perspiration
- 15 September 2020
- journal article
- research article
- Published by American Chemical Society (ACS) in ACS Chemical Health & Safety
- Vol. 27 (5) , 299-307
Abstract
Due to the COVID-19 pandemic, current high demand for N95 filtering facepiece respirators has placed them in short supply. Filtering facepiece respirator wearers have traditionally been instructed to discard their respirator and don a new one should the respirator become saturated with perspiration or damp from exhaled breath. However, today’s shortage may prohibit many N95 respirator wearers from replacing their filtering facepieces at this desired frequency. Previously unpublished research that evaluated the performance of N95 filtering facepiece respirators saturated with artificial perspiration and then dried out can help provide insight into making critical decisions about the change out frequency of N95 respirators that become damp with use. This study concluded that the collection efficiency of filtering facepiece respirators, containing electrostatic filter media, remained statistically unchanged or slightly improved after being dried out following harsh saturation conditions with artificial perspiration. Therefore, respirator wearers can continue to rely on their N95 filtering facepiece respirators to perform as intended.Keywords
Funding Information
- Lawrence Livermore National Laboratory (DE-AC52-07NA27344)
- Lawrence Livermore National Laboratory (LLNL-JRNL-809537)
This publication has 21 references indexed in Scilit:
- The Effects of Particle Charge on the Performance of a Filtering FacepieceAIHA Journal, 1998
- Collection of three bacterial aerosols by respirator and surgical mask filters under varying conditions of flow and relative humidityAnnals of Occupational Hygiene, 1997
- Mycobacterial Aerosol Collection Efficiency of Respirator and Surgical Mask Filters under Varying Conditions of Flow and HumidityApplied Occupational and Environmental Hygiene, 1997
- Quantitative Fit Testing Techniques and Regulations for Tight-Fitting Respirators: Current Methods Measuring Aerosol or Air Leakage, and New DevelopmentsAIHA Journal, 1997
- Fit Test for Filtering Facepieces: Search for a Low-Cost, Quantitative MethodAIHA Journal, 1994
- AEROSOL PENETRATION THROUGH FILTERING FACEPIECES AND RESPIRATOR CARTRIDGESAIHA Journal, 1992
- “Worst Case” Aerosol Testing Parameters: I. Sodium Chloride and Dioctyl Phthalate Aerosol Filter Efficiency as a Function of Particle Size and Flow RateAIHA Journal, 1989
- EFFECT OF INDUSTRIAL AEROSOLS ON THE PERFORMANCE OF ELECTRICALLY CHARGED FILTER MATERIALAnnals of Occupational Hygiene, 1988
- Performance of Dust Respirators with Facial Seal Leaks: I. ExperimentalAIHA Journal, 1987
- Electret filters for high-efficiency air cleaningJournal of Electrostatics, 1980