Abstract
Summary: The objective of this laboratory study was to compare root‐end cavities prepared with sonic Retro‐prep tips in a MM 1500 Sonic Air handpiece with those created by burs in a conventional handpiece. A total of 80 single‐rooted extracted human teeth with mature apices and straight canals were included in the study. Four groups of 20 extracted teeth were prepared as follows: I, a 3‐4 mm root‐end resection perpendicular to the long axis of the root, with a size 40 sonic Retro‐prep tip creating an apical cavity 3 mm into root canal system; II, a 45° bevel of the root‐face removing a 3‐4 mm root segment and root‐end preparation as per group I; III, root‐end resection as per group I, with an apical cavity prepared using a size 010 inverted cone bur 3 mm down the long axis of the root; IV, resection as per group II, followed by an apical cavity preparation with a size 010 inverted cone bur 3 mm into the root canal system. The apical root portion and root‐end cavities were replicated and prepared for SEM analysis at × 20 and × 80 magnification. The degree of chipping associated with the margin of the root‐end cavities, as evaluated with a standard grading system, and the incidence of root‐face cracks were noted. Marginal chipping of root‐end cavities prepared using sonic instrumentation was significantly worse than that produced by burs (P<0.001). Perpendicular root‐end resections showed significantly better scores than bevelled root‐end resections (P<0.005). The incidence of root‐face cracking was low with no significant difference between the experimental groups.

This publication has 25 references indexed in Scilit: