- 5 October 2021
- journal article
- research article
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 57 (4) , 205-211
Abstract
Objectives: This study aimed to evaluate the diagnostic performance of the maximum intensity projection (MIP) reformations of breast computed tomography (B-CT) images as a stand-alone method for the detection and characterization of breast imaging findings. Materials and Methods: A total of 160 women undergoing B-CT between August 2018 and December 2020 were retrospectively included; 80 patients with known breast imaging findings were matched with 80 patients without imaging findings according to age and amount of fibroglandular tissue (FGT). A total of 71 benign and 9 malignant lesions were included. Images were evaluated using 15-mm MIP in 3 planes by 2 radiologists with experience in B-CT. The presence of lesions and FGT were evaluated, using the BI-RADS classification. Interreader agreement and descriptive statistics were calculated. Results: The interreader agreement of the 2 readers for finding a lesion (benign or malignant) was 0.86 and for rating according to BI-RADS classification was 0.82. One of 9 cancers (11.1%) was missed by both readers due to dense breast tissue. BI-RADS 1 was correctly applied to 73 of 80 patients (91.3%) by reader 1 and to 74 of 80 patients (92.5%) by reader 2 without recognizable lesions. BI-RADS 2 or higher with a lesion in at least one of the breasts was correctly applied in 69 of 80 patients (86.3%) by both readers. For finding a malignant lesion, sensitivity was 88.9% (95% confidence interval [CI], 51.75%–99.72%) for both readers, and specificity was 99.3% (95% CI, 96.4%–100%) for reader 1 and 100% (95% CI, 97.20%–100.00%) for reader 2. Conclusions: Evaluation of B-CT images using the MIP reformations may help to reduce the reading time with high diagnostic performance and confidence.Keywords
This publication has 21 references indexed in Scilit:
- Potential Use of American College of Radiology BI-RADS Mammography Atlas for Reporting and Assessing Lesions Detected on Dedicated Breast CT ImagingAcademic Radiology, 2017
- Dedicated Breast CT: Screening Technique of the FutureCurrent Breast Cancer Reports, 2016
- Technical feasibility proof for high-resolution low-dose photon-counting CT of the breastEuropean Radiology, 2016
- Assessment of Interradiologist Agreement Regarding Mammographic Breast Density Classification Using the Fifth Edition of the BI-RADS AtlasAmerican Journal of Roentgenology, 2016
- Addition of Tomosynthesis to Conventional Digital Mammography: Effect on Image Interpretation Time of Screening ExaminationsRadiology, 2014
- The effect of mammography pain on repeat participation in breast cancer screening: A systematic reviewThe Breast, 2013
- Dedicated Cone-beam Breast Computed Tomography and Diagnostic Mammography: Comparison of Radiation Dose, Patient Comfort, And Qualitative Review of Imaging Findings in BI-RADS 4 and 5 LesionsJournal of Clinical Imaging Science, 2012
- Cone-Beam CT for Breast Imaging: Radiation Dose, Breast Coverage, and Image QualityAmerican Journal of Roentgenology, 2010
- Incremental Benefit of Maximum-Intensity-Projection Images on Observer Detection of Small Pulmonary Nodules Revealed by Multidetector CTAmerican Journal of Roentgenology, 2002
- STS-MIPJournal of Computer Assisted Tomography, 1993