Transient overvoltage response performance of transformer windings with short‐circuit fault
Authors:
Open Access
- 28 March 2018
- journal article
- research article
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 12 (10) , 2265-2272
Abstract
The fault diagnosis of transformer windings is a basis for condition maintenance. Conventional online or offline diagnosis methods require additional pulse or impulse signal. If the overvoltage signal can be regarded as the broadband excitation source for the fault diagnosis of transformer windings, the interference caused by signal injection is likely eliminated without additional pulse or impulse signals. In this study, the transient overvoltage response performance of transformer windings with short‐circuit fault is presented, which could provide a new method for the diagnosis on transformer fault diagnosis. A 10 kVA, 2400 V/220 V, 50 Hz, 1‐phase tapped transformer was designed, and a test platform for the fault diagnosis of transformer windings is established. The excitation signals for the fault diagnosis of the transformer windings included different lightning waves and damped oscillation waves, as indicated by the differences among actual overvoltage waveforms. The voltage and current of windings under normal and fault conditions are determined, and the frequency responses of admittance and voltage transfer function are calculated. The criterion for the fault diagnosis of transformer windings is obtained by comparing and analysing statistical indicators that reflected the differences in the frequency response of transfer function under normal and fault.Keywords
Funding Information
- Fundamental Research Funds for the Central Universities (106112014CDJZR155501, CDJZR14150001)
This publication has 29 references indexed in Scilit:
- Study on the Transfer Functions for Detecting Windings Displacement of Power Transformers with Impulse MethodJournal of Electrical Engineering & Technology, 2012
- Detection of power transformer winding deformation and variation of measurement connections using a hybrid winding modelElectric Power Systems Research, 2012
- A Smart Online Over-Voltage Monitoring and Identification SystemEnergies, 2011
- Sweep frequency response analysis (SFRA) for the assessment of winding displacements and deformation in power transformersElectric Power Systems Research, 2008
- Nonlinear scaled models in 3D calculation of transformer magnetic circuitsCOMPEL - The international journal for computation and mathematics in electrical and electronic engineering, 2006
- Improved Detection of Power Transformer Winding Movement by Extending the FRA High Frequency RangeIEEE Transactions on Power Delivery, 2005
- An Effort to Understand What Factors Affect the Transfer Function of a Two-Winding TransformerIEEE Transactions on Power Delivery, 2005
- Fault Diagnosis of a Power Transformer Using an Improved Frequency-Response AnalysisIEEE Transactions on Power Delivery, 2005
- Streaming electrification measurements in a 1/4-scale transformer modelIEEE Transactions on Power Delivery, 1999
- Impulse testing of power transformers using the transfer function methodIEEE Transactions on Power Delivery, 1988