Comparison of ECG-gated versus non-gated CT ventricular measurements in thirty patients with acute pulmonary embolism
- 15 July 2008
- journal article
- research article
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 25 (1) , 101-107
Abstract
Objective To prospectively compare cardiac ventricular measurements from non-gated CT and end-diastolic ECG-gated CT in patients with acute pulmonary embolism (PE). Materials and methods With institutional review board approval, 30 adult patients (16 female, mean age = 56 years, range = 26–77 years) underwent ECG-gated cardiac CT within 36 h of their CT diagnosis of acute PE to assess the right ventricle (RV). The axial and reformatted four-chamber ventricular diameters, areas and volumes were measured for both the non-gated CT and the ECG-gated CT in end-diastole and end-systole. Spearman’s rank correlation coefficient (RCC) was calculated to compare measurements from the non-gated CT to the gated end-diastolic measurements. The median absolute differences between the gated and non-gated measurements relative to the gated measurements were provided to summarize the degree to which the two measurements differ. A statistical model was constructed to test for potential improvement in specificity for the prediction of 30-day mortality after acute PE using right ventricular measurements from ECG-gated CT versus non-gated CT. Results The RCC (0.90 confidence interval) for non-gated and ECG-gated end-diastolic four-chamber and axial RV/LV diameter ratios were 0.83 (0.68–0.90) and 0.88 (0.74–0.95). The median absolute percent differences suggested a high degree of concordance between gated and non-gated measurements. The statistical model predicted that measuring the RV/LV diameter ratio from end-diastole using ECG-gated CT rather than non-gated CT would yield a potential improvement in specificity for death after PE of 0.035 (0.020–0.060) for axial diameter ratios and 0.035 (0.020–0.055) for four-chamber diameter ratios. Conclusion The benefit from a separate ECG-gated CT scan for the evaluation of RV ventricular diameter, area, and volume measurements is minimal and does not justify its routine clinical use.Keywords
This publication has 36 references indexed in Scilit:
- Reformatted Four-Chamber and Short-Axis Views of the Heart Using Thin Section (≤2 mm) MDCT ImagesAcademic Radiology, 2007
- How I Do It: CT Pulmonary AngiographyAmerican Journal of Roentgenology, 2007
- MDCT Assessment of Right Ventricular Systolic FunctionAmerican Journal of Roentgenology, 2006
- Computed tomographic pulmonary angiography and prognostic significance in patients with acute pulmonary embolismThorax, 2005
- Diagnosis of Right Ventricular Dysfunction in Acute Pulmonary Embolism Using Helical Computed TomographyThe American Journal of Cardiology, 2005
- Right Ventricular Enlargement on Chest Computed TomographyCirculation, 2004
- Right Ventricular Enlargement on Chest Computed TomographyCirculation, 2004
- Acute Pulmonary Embolism: Part ICirculation, 2003
- Echocardiography Doppler in pulmonary embolism: Right ventricular dysfunction as a predictor of mortality rateAmerican Heart Journal, 1997
- Indices of discrimination or diagnostic accuracy: Their ROCs and implied models.Psychological Bulletin, 1986