Estimation of geometrically undistorted B0inhomogeneity maps
Authors:
- 11 August 2014
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 59 (17) , 4945-4959
Abstract
Geometric accuracy of MRI is one of the main concerns for its use as a sole image modality in precision radiation therapy (RT) planning. In a state-of-the-art scanner, system level geometric distortions are within acceptable levels for precision RT. However, subject-induced B0 inhomogeneity may vary substantially, especially in air-tissue interfaces. Recent studies have shown distortion levels of more than 2 mm near the sinus and ear canal are possible due to subject-induced field inhomogeneity. These distortions can be corrected with the use of accurate B0 inhomogeneity field maps. Most existing methods estimate these field maps from dual gradient-echo (GRE) images acquired at two different echo-times under the assumption that the GRE images are practically undistorted. However distortion that may exist in the GRE images can result in estimated field maps that are distorted in both geometry and intensity, leading to inaccurate correction of clinical images. This work proposes a method for estimating undistorted field maps from GRE acquisitions using an iterative joint estimation technique. The proposed method yields geometrically corrected GRE images and undistorted field maps that can also be used for the correction of images acquired by other sequences. The proposed method is validated through simulation, phantom experiments and applied to patient data. Our simulation results show that our method reduces the root-mean-squared error of the estimated field map from the ground truth by ten-fold compared to the distorted field map. Both the geometric distortion and the intensity corruption (artifact) in the images caused by the B0 field inhomogeneity are corrected almost completely. Our phantom experiment showed improvement in the geometric correction of approximately 1 mm at an air-water interface using the undistorted field map compared to using a distorted field map. The proposed method for undistorted field map estimation can lead to improved geometric distortion correction at air-tissue interfaces, especially in low readout-bandwidth acquisitions, thus making them suitable for clinical use in precision RT without increasing the treatment planning margin.Keywords
This publication has 18 references indexed in Scilit:
- Predictive and Prognostic Role of Functional Imaging of Head and Neck Squamous Cell CarcinomasSeminars in Radiation Oncology, 2012
- The Promise of Dynamic Contrast-Enhanced Imaging in Radiation TherapySeminars in Radiation Oncology, 2011
- Consensus Guidelines for Delineation of Clinical Target Volume for Intensity-Modulated Pelvic Radiotherapy for the Definitive Treatment of Cervix CancerInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2011
- Real-time correction of magnetic field inhomogeneity-induced image distortions for MRI-guided conventional and proton radiotherapyPhysics in Medicine & Biology, 2010
- Recommendations from Gynaecological (GYN) GEC-ESTRO Working Group☆ (I): concepts and terms in 3D image based 3D treatment planning in cervix cancer brachytherapy with emphasis on MRI assessment of GTV and CTVRadiotherapy and Oncology, 2005
- Impact of magnetic resonance imaging versus CT on nasopharyngeal carcinoma: primary tumor target delineation for radiotherapyHead & Neck, 2004
- Fast, automated, N‐dimensional phase‐unwrapping algorithmMagnetic Resonance in Medicine, 2002
- Spatial resolution properties of penalized-likelihood image reconstruction: space-invariant tomographsIEEE Transactions on Image Processing, 1996
- Correction for geometric distortion in echo planar images from B0 field variationsMagnetic Resonance in Medicine, 1995
- A technique for accurate magnetic resonance imaging in the presence of field inhomogeneitiesIEEE Transactions on Medical Imaging, 1992