Abstract
In order to prevent smoke from flowing backward and penetrating into adjacent tunnel through cross channels during evacuation in case of fire accidents in highway tunnels, it is extremely necessary to implement the linkage control scheme for double‐hole tunnel ventilation system. Therefore, six linkage control schemes for ventilation system are proposed in this article. Firstly, these six schemes were numerically simulated through Fire Dynamics Simulator (FDS) to obtain the flow velocity, flow direction, and smoke distribution under different schemes when the peak power of fire accidents is 30 MW. And two better schemes were selected for further investigation based on the evacuation conditions in the upper stream of fire source. Secondly, a 1 : 10 scale model experiment was conducted to test these two schemes, and the results from numerical simulation and model experiment were compared and verified. Finally, the location of fire accident, the time to develop stable opposite airflow, and the number of open cross channels were analyzed to confirm the applicability of the recommended scheme. The results show that the optimal scheme is to switch on the fans in the upstream of the fire accident and the fans on both sides of the cross channel in the non‐fire tunnel to form positive pressure to control the smoke flow. This scheme ensures a stable and uniform smoke flow in the cross channel and personnel’s safety during evacuation.Keywords
Funding Information
- National Natural Science Foundation of China (51678530)
This publication has 9 references indexed in Scilit:
- Wind and Fire Coupled Modelling—Part I: Literature ReviewFire Technology, 2018
- Wind and Fire Coupled Modelling—Part II: Good Practice GuidelinesFire Technology, 2018
- Numerical analysis of smoke dispersion against the wind in a tunnel fireJournal of Wind Engineering and Industrial Aerodynamics, 2016
- Influence of Train Location on Smoke Control in Tunnel Cross-passageProcedia Engineering, 2016
- Numerical study of the effect of blockage on critical velocity and backlayering length in longitudinally ventilated tunnel firesTunnelling and Underground Space Technology, 2015
- Reduced-scale Experimental Research on Fires in Tunnels with Natural VentilationProcedia Engineering, 2013
- Theoretical and Experimental Study of Critical Velocity for Smoke Control in a Tunnel Cross-PassageFire Technology, 2010
- Control of smoke flow in tunnel fires using longitudinal ventilation systems – a study of the critical velocityFire Safety Journal, 2000
- Fire protection in traffic tunnels: General aspects and results of the EUREKA projectTunnelling and Underground Space Technology, 1998