Reproducibility of Central Corneal Thickness Measurements in Healthy and Glaucomatous Eyes
Authors:
- 1 September 2017
- journal article
- oiginal studies
- Published by Wolters Kluwer Health in Journal of Glaucoma
- Vol. 26 (9) , 787-791
Abstract
Purpose: The purpose of this study is to characterize intraday and interday variation in central corneal thickness (CCT) in healthy and glaucomatous subjects. Methods: In this prospective cohort study, 40 healthy subjects and 42 subjects with primary open-angle glaucoma underwent CCT measurements by ultrasonic pachymetry on 5 days over 1 year: first at baseline, then at 1 week and 1, 6, and 12 months after baseline. On 1visit, CCT was measured every 2 hours from 08:00 to 20:00. Intraday CCT variance was compared with interday CCT variance. Results: Mean CCT at all visits and time points ranged from 561 to 574 µm in healthy eyes and from 548 to 563 µm in glaucomatous eyes. The mean intraday CCT range (highest minus lowest readings) was 21±10 µm in healthy participants and 21±10 µm in glaucoma patients. The mean interday CCT range was 27±13 µm in healthy participants and 24±14 µm in glaucoma patients. Within-subject variance was significantly larger among the interday CCT measurements than the intraday CCT measurements in both healthy subjects and glaucoma patients (P<0.0001 for both) demonstrating that measurements taken on separate days are more different than measurements taken on the same day. Interday CCT differences of ≥30 µm were seen in 27.7% of normal subjects and 30% of glaucoma patients. Conclusions: CCT measurements exhibit intraday and interday variation, with the latter being significantly greater than the former. A single CCT assessment inadequately characterizes CCT and may impact risk assessment in patients with suspect and/or diagnosed glaucoma.Keywords
This publication has 22 references indexed in Scilit:
- Central Corneal Thickness as a Predictor of Visual Field Loss in Primary Open Angle Glaucoma for a Hispanic PopulationSeminars in Ophthalmology, 2011
- The Relationship between Diurnal Variations in Intraocular Pressure Measurements and Central Corneal Thickness and Corneal HysteresisInvestigative Ophthalmology & Visual Science, 2009
- Correlation between diurnal variation of intraocular pressure, ocular pulse amplitude and corneal structural propertiesArquivos Brasileiros de Oftalmologia, 2009
- Central Corneal Thickness and Visual Field Progression in Patients With Chronic Primary Angle-closure Glaucoma With Low Intraocular PressureAmerican Journal of Ophthalmology, 2007
- Central Corneal Thickness and Visual Field Loss in Fellow Eyes of Patients With Open-Angle GlaucomaAmerican Journal of Ophthalmology, 2007
- Validated Prediction Model for the Development of Primary Open-Angle Glaucoma in Individuals with Ocular HypertensionOphthalmology, 2007
- Central Corneal Thickness and Corneal Hysteresis Associated With Glaucoma DamageAmerican Journal of Ophthalmology, 2006
- Central corneal thickness: Will one measurement suffice?Ophthalmology, 2005
- Risk assessment in the management of patients with ocular hypertensionAmerican Journal of Ophthalmology, 2004
- Diurnal variations in human corneal thickness.British Journal of Ophthalmology, 1996