ESD field coupling study in relation with PCB GND and metal chassis
- 1 January 2009
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 153-156
Abstract
This work demonstrates a simple experimental setup to measure ESD-induced voltage to traces on a printed circuit board when ESD current is injected directly onto the outside of a metal case and presents how the induced voltage can be affected by the physical structure of the PCB ground and the metal case. The correlation between ESD-induced voltage and the method of connecting the PCB and chassis grounds shall be discussed, as well as how the PCB ground fill affects ESD. These experimental results may provide guidance for a better design for ESD immunity.Keywords
This publication has 3 references indexed in Scilit:
- Advanced full wave ESD generator model for system level coupling simulation2008
- Numerical Prediction and Measurement of ESD Radiated Fields by Free-Space Field SensorsIEEE Transactions on Electromagnetic Compatibility, 2007
- Numerical modeling of ESD-simulators2003