Original studies: Comparison of angiography and intravascular ultrasound for the assessment of lumen size after coronary stent placement: Impact of dilation pressures
Authors:
- 1 October 1997
- journal article
- research article
- Published by Wiley in Catheterization and Cardiovascular Diagnosis
- Vol. 42 (2) , 113-119
Abstract
This study was designed to assess the extent of potential discrepancies between intravascular ultrasound (IVUS) and quantitative coronary angiography (QCA) measurement of intrastent minimal luminal diameter and to evaluate the impact of dilation pressures and the balloon:artery ratio on the assessment of the minimal lumen diameter (MLD) by these imaging modalities. IVUS is recommended as an adjunct to angiography to assess stent expansion; however, the extent of potential discrepancies between the two imaging modalities is not well defined. Included were 225 patients in whom coronary Palmaz-Schatz stents were successfully placed after PTCA. IVUS and QCA were performed at the end of the intervention. We compared the MLD assessed by QCA and IVUS in the instent and reference site. The MLD assessed by IVUS and QCA were 2.68 ± 0.41 mm and 3.08 ± 0.47 mm (P < 0.001), respectively, at the tightest intrastent site and 3.19 ± 0.50 mm and 3.17 ± 0.52 ns at the reference site. There was a correlation between the dilation pressure and the difference between QCA- and IVUS-based intrastent MLD measurement (y = −0.05x + 1.11; r = −0.53; P < 0.0001). At low dilation pressures, a significant difference beween the image modalities was found, but after high dilation pressures no discrepancies were detected. No relation was found with the balloon:artery ratio. These data provide clear evidence that in the case of low-pressure dilation, the exclusive reliance on data obtained by QCA will not yield sufficiently accurate information on intrastent MLD, whereas after high dilation pressure, the differences between the imaging modalities are minimized. Cathet. Cardiovasc. Diagn. 42:113–119, 1997.Keywords
This publication has 30 references indexed in Scilit:
- Intracoronary Stenting Without Anticoagulation Accomplished With Intravascular Ultrasound GuidanceCirculation, 1995
- Four-year experience with Palmaz-Schatz stenting in coronary angioplasty complicated by dissection with threatened or present vessel closure.Circulation, 1994
- Time course of restenosis during the first year after emergency coronary stenting.Circulation, 1993
- Left ventricular filling pattern in -thalassaemia major -- a Doppler echocardiographic studyEuropean Heart Journal, 1993
- Intravascular ultrasound: a histological study of vessels during life. The new 'gold standard' for vascular imaging.Circulation, 1992
- Intracoronary stenting for acute and threatened closure complicating percutaneous transluminal coronary angioplasty.Circulation, 1992
- Relative risk analysis of angiographic predictors of restenosis within the coronary Wallstent.Circulation, 1991
- Intravascular ultrasound imaging of human coronary arteries in vivo. Analysis of tissue characterizations with comparison to in vitro histological specimens.Circulation, 1991
- The Reproducibility of Intravascular Ultrasound Imaging In VitroJournal of the American Society of Echocardiography, 1990
- Application of a new phased-array ultrasound imaging catheter in the assessment of vascular dimensions. In vivo comparison to cineangiography.Circulation, 1990