Graphene oxide modified light addressable potentiometric sensor and its application for ssDNA monitoring
- 2 October 2012
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 137 (24) , 5866-5873
Abstract
A light addressable potentiometric sensor (LAPS) is a kind of silicon based semiconductor sensor, and surface modification is a fundamental problem for its application in biological fields. Graphene oxide (GO) based biochemically activated LAPS were proposed, called GO-LAPS. The GO-LAPS were applied to monitoring single strand DNA (ssDNA) probe immobilization and its hybridization with complementary ssDNA molecules of different chain lengths (30, 21 and 14 base pairs, respectively). It was discovered that the curves of LAPS' currents versus analyte concentrations for ssDNA probe binding and the target ssDNA hybridization were different. Explanations were proposed based on the semiconductor's surface-electric-field-effect and the electrical properties of ssDNA molecule. Moreover, comparisons between GO-LAPS and LAPS without GO modification were carried out. Enhanced response currents of GO-LAPS were reported experimentally and analyzed theoretically based on X-ray photoelectron spectroscopy (XPS) of GO-LAPS. The limitation of target ssDNA monitoring was 1 pM to 10 nM, which suggested that this LAPS based platform could be developed as a sensitive means for short chain ssDNA detection.Keywords
This publication has 26 references indexed in Scilit:
- Label-free colorimetric sensor for ultrasensitive detection of heparin based on color quenching of gold nanorods by graphene oxideBiosensors and Bioelectronics, 2012
- Functional nucleic acids for electrochemical and electrochemiluminescent sensing applicationsTrAC Trends in Analytical Chemistry, 2012
- Cell Biocompatibility of Functionalized Graphene OxideActa Physico-Chimica Sinica, 2012
- Surface Doping of Conjugated Polymers by Graphene Oxide and Its Application for Organic Electronic DevicesAdvanced Materials, 2011
- Development of electrochemical DNA biosensor for Trichoderma harzianum based on ionic liquid/ZnO nanoparticles/chitosan/gold electrodeJournal of Solid State Electrochemistry, 2011
- The electrochemiluminescence of ruthenium complex/tripropylamine systems at DNA-modified gold electrodesBiosensors and Bioelectronics, 2011
- Graphene for electrochemical sensing and biosensingTrAC Trends in Analytical Chemistry, 2010
- Chemically Derived Graphene Oxide: Towards Large‐Area Thin‐Film Electronics and OptoelectronicsAdvanced Materials, 2010
- Screen printing as cost-efficient fabrication method for DNA-chips with electrical readout for detection of viral DNABiosensors and Bioelectronics, 2009
- Structural and electronic property changes of the nucleic acid bases upon base pair formationJournal of Computational Chemistry, 1994