Using heterogeneous sensory measurements in a compliant magnetic localization system for medical intervention
- 1 July 2015
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21596247,p. 133-138
Abstract
In many medical intervention procedures, passive magnetic tracking technology has found favor in continuous localization of medical instruments and tools inside the human body. By utilizing a small permanent magnet as a passive source, it requires no dedicated power supply or wire connection into the body. Past researches usually adopt rigid structures to restrict the movement of sensors, as the precise positional information of the homogeneous magnetic sensors play an important role in the accuracy of traditional inverse optimization algorithms. In this paper, we investigate methods to enable the sensing system to be used for the nasogastric (NG) tube localization in a compliant setting, such that the device can conform around the patient for improved ergonomics and comfort. Such a system, which now contains additional sensors required to sense the active compliance, will contain a non-homogeneous sensor assembly producing heterogeneous sensory information. Two methods are proposed and evaluated: one is a modified inverse optimization method using a deformation model in series with the magnetic field model; the other is a direct forward Artificial Neural Network (ANN) method. The efficacy of both methods were evaluated and compared by numerical simulation and experiments. Advantages and disadvantages of both methods were discussed at the end.Keywords
This publication has 12 references indexed in Scilit:
- Design and analysis of a compliant non-invasive real-time localization system for nasogastric intubation2014
- Optimal spatial design of non-invasive magnetic field-based localization systems2014
- Enhanced magnetic localization with artificial neural network field models2013
- A compact two DOF magneto-elastomeric force sensor for a running quadruped2012
- Placement of External Ventricular Drains and Intracranial Pressure Monitors by NeurointensivistsNeurocritical Care, 2008
- Sensor Arrangement Optimization of Magnetic Localization and Orientation system2007
- A Localization Method Using 3-axis Magnetoresistive Sensors for Tracking of Capsule Endoscope2006
- Noninvasive Verification of Nasogastric Tube Placement Using a Magnet‐Tracking System: A Pilot Study in Healthy SubjectsJournal of Parenteral and Enteral Nutrition, 2005
- Tracking system with five degrees of freedom using a 2D-array of Hall sensors and a permanent magnetSensors and Actuators A: Physical, 2001
- An inverse problem of magnetic source localizationNumerical Algorithms, 1993