Using the Compressed Sensing Technique for Lumbar Vertebrae Imaging: Comparison with Conventional Parallel Imaging
Open Access
- 1 August 2021
- journal article
- research article
- Published by Bentham Science Publishers Ltd. in Current Medical Imaging
- Vol. 17 (8) , 1010-1017
Abstract
Objective: To compare conventional sensitivity encoding turbo spin-echo (SENSE-TSE) with compressed sensing plus SENSE turbo spin-echo (CS-TSE) in lumbar vertebrae magnetic resonance imaging (MRI). Methods: This retrospective study of lumbar vertebrae MRI included 600 patients; 300 patients received SENSE-TSE and 300 patients received CS-TSE. The SENSE acceleration factor was 1.4 for T1WI, 1.7 for T2WI, and 1.7 for PDWI. The CS total acceleration factor was 2.4, 3.6, 4.0, and 4.0 for T1WI, T2WI, PDWI sagittal, and T2WI transverse, respectively. The image quality of each MRI sequence was evaluated objectively by the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) and subjectively on a five-point scale. Two radiologists independently reviewed the MRI sequences of the 300 patients receiving CS-TSE, and their diagnostic consistency was evaluated. The degree of intervertebral foraminal stenosis and nerve root compression was assessed using the T1WI sagittal and T2WI transverse images. Results: The scan time was reduced from 7 min 28 s to 4 min 26 s with CS-TSE. The median score of nerve root image quality was 5 (p > 0.05). The diagnostic consistency using CS-TSE images between the two radiologists was high for diagnosing lumbar diseases (κ > 0.75) and for evaluating the degree of lumbar foraminal stenosis and nerve root compression (κ = 0.882). No differences between SENSE-TSE and CS-TSE were observed for sensitivity, specificity, positive predictive value, or negative predictive value. Conclusion: CS-TSE has the potential for diagnosing lumbar vertebrae and disc disorders.Keywords
Funding Information
- Natural Science Foundation of Liaoning Province (2019-ZD-0794)
- National Natural Science Foundation of China (30871211, 81271538)
This publication has 30 references indexed in Scilit:
- Clinical performance of contrast enhanced abdominal pediatric MRI with fast combined parallel imaging compressed sensing reconstructionJournal of Magnetic Resonance Imaging, 2013
- Compressed sensing MRI combined with SENSE in partialk-spacePhysics in Medicine & Biology, 2012
- An updated overview of clinical guidelines for chronic low back pain management in primary careJoint Bone Spine, 2012
- Qualitative Grading of Severity of Lumbar Spinal Stenosis Based on the Morphology of the Dural Sac on Magnetic Resonance ImagesSpine, 2010
- A Practical MRI Grading System for Lumbar Foraminal StenosisAmerican Journal of Roentgenology, 2010
- MR Imaging in Osteoarthritis: Hardware, Coils, and SequencesRadiologic Clinics of North America, 2009
- Sparse MRI: The application of compressed sensing for rapid MR imagingMagnetic Resonance in Medicine, 2007
- Signal‐to‐noise ratio and parallel imaging performance of a 16‐channel receive‐only brain coil array at 3.0 TeslaMagnetic Resonance in Medicine, 2003
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999
- Fat Suppression in MR Imaging: Techniques and PitfallsRadioGraphics, 1999