Diagnostic neutral beam injector for active spectroscopy of high beta plasmas
Open Access
- 1 June 2024
- journal article
- research article
- Published by AIP Publishing in AIP Advances
- Vol. 14 (6)
Abstract
The advanced fast ion-dominated high beta plasma is achieved using multi-MW neutral heating beams. To facilitate the diagnostics of this fast ion-dominated plasma, a high-energy and high-current diagnostic neutral beam (DNB) injector was designed and built by the Budker Institute of Nuclear Physics. The DNB injector made active measurements of ion temperature and rotational velocity possible with the help of charge-exchange spectroscopy for impurity ions and, most importantly, for the main ion (deuterium) component. A DNB energy of 40 keV was chosen to assure low beam attenuation in the plasma and to enable spectroscopic measurements along the entire plasma column. The diameter (level 1/e) of the ballistically focused DNB in the plasma is about 8 cm. To achieve a high temporal resolution, unique methods of beam modulation with a frequency of up to 10 kHz were implemented. The achieved high DNB current of 8 A in atomic hydrogen in combination with the beam modulation enables to obtain an acceptable signal-to-noise ratio of the measured spectra.Keywords
This publication has 13 references indexed in Scilit:
- Upgraded main ion charge exchange recombination spectroscopy on the C-2W field reversed configuration (FRC) plasmaReview of Scientific Instruments, 2022
- Measurements of impurity ion temperature and velocity distributions via active charge-exchange recombination spectroscopy in C-2WReview of Scientific Instruments, 2021
- Low energy, high power hydrogen neutral beam for plasma heatingReview of Scientific Instruments, 2015
- Active beam spectroscopy for ITERNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2010
- Charge exchange recombination spectroscopy on a diagnostic hydrogen beam—measuring impurity rotation and radial electric field at the tokamak TEXTORJournal of Physics B: Atomic, Molecular and Optical Physics, 2010
- Long-pulse arc-discharge plasma source with cold cathode for diagnostic neutral beam injectorReview of Scientific Instruments, 2008
- Diagnostic neutral beam and active spectroscopy requirements for the Alcator C-Mod tokamak (invited)Review of Scientific Instruments, 1997
- Radial electric field measurement in a tokamak by the injection of a pulsed neutral beamPlasma Physics and Controlled Fusion, 1994
- Hydrogen and deuterium ion species mix and injected neutral beam power fractions of the TEXTOR–PINIs for 20–60 kV determined by Doppler shift spectroscopyReview of Scientific Instruments, 1993
- Local ion temperature measurements from Doppler broadening of hydrogen lines using a fast atomic beamNuclear Fusion, 1985